PMN8118UWP Ericsson Power Modules, PMN8118UWP Datasheet - Page 3

DC/DC Converters & Regulators 0.7-3.6V 30A Non-Iso Input 5.5-14V 108W

PMN8118UWP

Manufacturer Part Number
PMN8118UWP
Description
DC/DC Converters & Regulators 0.7-3.6V 30A Non-Iso Input 5.5-14V 108W
Manufacturer
Ericsson Power Modules
Series
PMNr
Datasheet

Specifications of PMN8118UWP

Output Power
108 W
Input Voltage Range
5.5 V to 14 V
Number Of Outputs
1
Output Voltage (channel 1)
0.7 V to 3.6 V
Output Current (channel 1)
30 A
Output Type
POLA Non-Isolated Regulator
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PMN8118UWP
Manufacturer:
WE
Quantity:
12 000
E
Prepared (also subject responsible if other)
EWEIXIE
Approved
SEC/D (Julia You)
PMN 8000 series PoL Regulator
Input 5.5 - 14 V, Output up to 30 A / 108 W
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC regulators are
designed in accordance with safety standards IEC/EN/UL60950, Safety
of Information Technology Equipment.
IEC/EN/UL60950 contains requirements to prevent injury or damage
due to the following hazards:
On-board DC-DC converters and DC/DC regulators are defined as
component power supplies. As components they cannot fully comply
with the provisions of any Safety requirements without “Conditions of
Acceptability”. Clearance between conductors and between conductive
parts of the component power supply and conductors on the board in
the final product must meet the applicable Safety requirements. Certain
conditions of acceptability apply for component power supplies with
limited stand-off (see Mechanical Information for further information). It
is the responsibility of the installer to ensure that the final product
housing these components complies with the requirements of all
applicable Safety standards and Directives for the final product.
Component power supplies for general use should comply with the
requirements in IEC60950, EN60950 and UL60950 “Safety of
information technology equipment”.
There are other more product related standards, e.g. IEEE802.3af
“Ethernet LAN/MAN Data terminal equipment power”, and ETS300132-2
“Power supply interface at the input to telecommunications equipment;
part 2: DC”, but all of these standards are based on IEC/EN/UL60950
with regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC regulators are
UL60950 recognized and certified in accordance with EN60950.
The flammability rating for all construction parts of the
products meets requirements for V-0 class material according to IEC
60695-11-10.
The products should be installed in the end-use equipment, in
accordance with the requirements of the ultimate application. Normally
the output of the DC/DC converter is considered as SELV (Safety Extra
Low Voltage) and the input source must be isolated by minimum Double
or Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL60950.
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
Checked
EMINTAO
Ericsson Internal
PRODUCT SPECIFICATION
No.
1/1301-BMR656 8118 Uen
Date
2007-07-30
Isolated DC/DC converters
It is recommended that a slow blow fuse with a rating twice the
maximum input current per selected product be used at the input of
each DC/DC converter. If an input filter is used in the circuit the fuse
should be placed in front of the input filter.
In the rare event of a component problem in the input filter or in the
DC/DC converter that imposes a short circuit on the input source, this
fuse will provide the following functions:
The galvanic isolation is verified in an electric strength test.
The test voltage (V
1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification).
Leakage current is less than 1 µA at nominal input voltage.
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under normal and
abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to the DC/DC converter is 75 Vdc or less, then the
output remains SELV (Safety Extra Low Voltage) under normal and
abnormal operating conditions.
Single fault testing in the input power supply circuit should be performed
with the DC/DC converter connected to demonstrate that the input
voltage does not exceed
75 Vdc.
If the input power source circuit is a DC power system, the source may
be treated as a TNV2 circuit and testing has demonstrated compliance
with SELV limits and isolation requirements equivalent to Basic
Insulation in accordance with IEC/EN/UL60950.
Non-isolated DC/DC regulators
The input voltage to the DC/DC regulator is SELV (Safety
Extra Low Voltage) and the output remains SELV under normal and
abnormal operating conditions.
Isolate the faulty DC/DC converter from the input power
source so as not to affect the operation of other parts of the
system.
Protect the distribution wiring from excessive current and
power loss thus preventing hazardous overheating.
iso
Technical Specification
EN/LZT 146 387 R1B December 2009
© Ericsson AB
) between input and output is
Rev
B
Reference
3 (4)
3