PKB4713PINB Ericsson Power Modules, PKB4713PINB Datasheet

PKB4713PINB
Specifications of PKB4713PINB
Available stocks
Related parts for PKB4713PINB
PKB4713PINB Summary of contents
Page 1
E Prepared (also subject responsible if other) EZHIXZH Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Key Features • Industry standard Eighth-brick 58.4 x 22.7 x 8.10 mm (2.30 x 0.894 x ...
Page 2
... Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’ ...
Page 3
... Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. ...
Page 4
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W Absolute Maximum Ratings Characteristics T Operating Temperature (see Thermal Consideration section) ref T Storage temperature S V ...
Page 5
Prepared (also subject responsible if other) ESECZHW Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.0 V/30 A Electrical Specification T = -40 to +90º sense ...
Page 6
Prepared (also subject responsible if other) ESECZHW Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.0 V/30 A Typical Characteristics Efficiency [%] ...
Page 7
Prepared (also subject responsible if other) ESECZHW Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.0 V/30 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (0.5 ...
Page 8
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.2 V/30 A Electrical Specification T = -40 to +90º sense ...
Page 9
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.2V/30 A Typical Characteristics Efficiency [%] ...
Page 10
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.2V/30 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (0.5 V/div.). ...
Page 11
Prepared (also subject responsible if other) ESHUHAN Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.5 V/30 A Electrical Specification T = -40 to +90º sense ...
Page 12
Prepared (also subject responsible if other) ESHUHAN Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.5V/30 A Typical Characteristics Efficiency [%] ...
Page 13
Prepared (also subject responsible if other) ESHUHAN Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.5V/30 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (0.5 V/div.). ...
Page 14
Prepared (also subject responsible if other) EGLANDY Approved PKB 4000 series SEC/D (ALICE SU) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.8 V/25 A Electrical Specification T = -40 to +90º sense ...
Page 15
Prepared (also subject responsible if other) EGLANDY Approved PKB 4000 series SEC/D (ALICE SU) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.8 V/25 A Typical Characteristics Efficiency [%] ...
Page 16
Prepared (also subject responsible if other) EGLANDY Approved PKB 4000 series SEC/D (ALICE SU) DC/DC converters, Input 36-75 V, Output 30 A/90 W 1.8 V/25 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (1 ...
Page 17
Prepared (also subject responsible if other) EXUEFYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 2.5 V/25 A Electrical Specification T = -40 to +90º sense ...
Page 18
Prepared (also subject responsible if other) EXUEFYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 2.5 V/25 A Typical Characteristics Efficiency [%] ...
Page 19
Prepared (also subject responsible if other) EXUEFYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W 2.5 V/25 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (2 ...
Page 20
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/20 A Electrical Specification T = -40 to +90º sense ...
Page 21
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/20A Typical Characteristics Efficiency [%] Efficiency ...
Page 22
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/20 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (2 ...
Page 23
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/25 A Electrical Specification T = -40 to +90º sense ...
Page 24
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/25A Typical Characteristics Efficiency [%] ...
Page 25
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 3.3 V/25 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (2 ...
Page 26
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 5.0 V/15 A Electrical Specification T = -40 to +90º sense ...
Page 27
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 5.0 V/15 A Typical Characteristics Efficiency [%] ...
Page 28
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/90 W 5.0 V/15 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (2 ...
Page 29
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/6 A Electrical Specification T = -40 to +90º sense ...
Page 30
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/6 A Typical Characteristics Efficiency [%] ...
Page 31
Prepared (also subject responsible if other) ECHWANG Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/6 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (5 ...
Page 32
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/7.5 A Electrical Specification T = -40 to +90º sense ...
Page 33
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/7.5A Typical Characteristics Efficiency [%] Efficiency ...
Page 34
Prepared (also subject responsible if other) EZYPING Approved PKB 4000 series SEC/D (Betty Wu) DC/DC converters, Input 36-75 V, Output 30 A/ V/7.5 A Typical Characteristics Start-up Start-up enabled by connecting VI at: Top trace: output voltage 5 ...
Page 35
Prepared (also subject responsible if other) EYINGJI Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/ V/5 A Electrical Specification T = -40 to +90º sense ...
Page 36
Prepared (also subject responsible if other) EYINGJI Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/ V/5 A Typical Characteristics Efficiency [%] ...
Page 37
Prepared (also subject responsible if other) EYINGJI Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/ V/5 A Typical Characteristics Start-up Start-up enabled by connecting V at: Top trace: output voltage (5 ...
Page 38
Prepared (also subject responsible if other) EJUNGYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). ...
Page 39
Prepared (also subject responsible if other) EJUNGYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Operating information Input Voltage The input voltage range 36 to 75Vdc meets the requirements of the European ...
Page 40
Prepared (also subject responsible if other) EJUNGYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Operating information continued Parallel Operation Two converters may be paralleled for redundancy if the total power is ...
Page 41
Prepared (also subject responsible if other) EJUNGYA Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Thermal Consideration continued Definition of reference temperature (T The reference temperature is used to monitor the temperature ...
Page 42
Prepared (also subject responsible if other) EPANHON Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Mechanical Information - Surface mount version PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 636 Uen Checked Date See §1 ...
Page 43
Prepared (also subject responsible if other) EPANHON Approved PKB 4000 series SEC/D (Julia You) DC/DC converters, Input 36-75 V, Output 30 A/90 W Mechanical Information- Through hole mount version PRODUCT SPEC. MECHANICAL No. 4/1301-BMR 636 Uen Checked Date See §1 ...
Page 44
Prepared (also subject responsible if other) EPANHON Approved PKB 4000 series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 30 A/90 W Soldering Information - Surface Mounting The surface mount version of the product is intended for convection or ...
Page 45
Prepared (also subject responsible if other) EPANHON Approved PKB 4000 series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 30 A/90 W Soldering Information — Through Hole Mounting The through hole mount version of the product is intended for ...
Page 46
Prepared (also subject responsible if other) EPANHON Approved PKB 4000 series SEC/D [Julia You] DC/DC converters, Input 36-75 V, Output 30 A/90 W Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature IEC 60068-2-14 Na (Temperature cycling) Cold ...