SI2707-A10-GM Silicon Laboratories Inc, SI2707-A10-GM Datasheet - Page 30

AMPLIFIER AUDIO CLASS D 24QFN

SI2707-A10-GM

Manufacturer Part Number
SI2707-A10-GM
Description
AMPLIFIER AUDIO CLASS D 24QFN
Manufacturer
Silicon Laboratories Inc
Type
Class Dr
Datasheet

Specifications of SI2707-A10-GM

Output Type
2-Channel (Stereo) with Stereo Headphones
Package / Case
24-VFQFN Exposed Pad
Max Output Power X Channels @ Load
5W x 2 @ 3 Ohm
Voltage - Supply
4 V ~ 6.6 V
Features
Depop, I²S, Short-Circuit and Thermal Protection, Tone and Volume Control
Mounting Type
Surface Mount
Product
Class-D
Output Power
5 W
Thd Plus Noise
0.1 %
Supply Current
100 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Audio Load Resistance
8 Ohms
Input Offset Voltage
Minimum Operating Temperature
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
336-1928

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI2707-A10-GM
Quantity:
457
Si2704/05/06/07-A10
Figure 24. Time Domain Characteristics of the Audio Dynamic Range Controller
4.6.7. Hard Signal Limiter
The device implements a hard limiter to avoid exceeding the maximum modulation rate of the amplifier. The hard
limiter is always enabled.
4.6.8. DC Notch Filter
A dc notch filter with a 5 Hz corner frequency is implemented as the final function in the signal processing chain to
remove any dc component from the output signal. Each channel has a separate dc notch filter.
4.6.9. Tone and Alert Generation
The Si270x includes two independent tone generators with programmable frequencies and on/off times.
2
The output of both tone generators is fed to a mixer which combines the tones with the I
S inputs. The tones’
amplitudes can be adjusted by programming the mixer coefficients using the SET_AUDIO_INPUT_MIXER
command.
This feature allows customization of audible alarms and alerts. Programmable frequencies range from 100 Hz to
20 kHz in 100 Hz steps and on/off times range from 0 to 65 seconds in 1 ms steps and are set via the 2-Wire
interface using the properties TONE_ONE_FREQ, TONE_ONE_ON_TIME, TONE_ONE_OFF_TIME, and
TONE_ONE_AMPLITUDE
for
the
first
tone
and
TONE_TWO_FREQ,
TONE_TWO_ON_TIME,
TONE_TWO_OFF_TIME, and TONE_TWO_AMPLITUDE for the second tone.
4.7. Fault Detection and Response
To help protect the H-bridge driver and external loads, the output stage has fault detection circuitry that allows the
device to respond to over-current and over-temperature events.
The over-temperature circuitry monitors the temperature of the device and if the temperature exceeds 135 ºC a
thermal error is issued, and the output stage is shut down by transitioning the device to Standby Mode.
The over-current protection circuit constantly monitors the current of the output stage and triggers a fault alarm if
an over-current condition is detected from three different events: a short circuit across the speaker terminals, a
short circuit of any of the outputs to ground and a short circuit of any of the outputs to the supply voltage. In each
case, the detector issues a fault if the 2.5 A current threshold is exceeded. In response to this fault the device
power stage is shut down by transitioning the device to Standby Mode.
30
Rev. 0.6

Related parts for SI2707-A10-GM