ZSE40-T1-62 SMC Corporation of America, ZSE40-T1-62 Datasheet - Page 3

no-image

ZSE40-T1-62

Manufacturer Part Number
ZSE40-T1-62
Description
SENSOR VACUUM 101.3KPA PNP/ ANLG
Manufacturer
SMC Corporation of America
Series
ZSE40r
Datasheet

Specifications of ZSE40-T1-62

Pressure Type
Vacuum
Operating Pressure
-14.65 ~ 1.45 PSI, -101 ~ +10 kPa
Port Size
Female, 1/8" (3.175mm) NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1011
Description
Calibration Procedures
Setting procedure
Set “Output mode”, “Response
time” and “Auto or Manual
mode”.
Initial setting
Displays present pressure.
Displays each mode.
Displays error mode.
Switching of the mode and set value
Displays OUT1 output condition
When it is ON, the LED is
illuminated.
LED (Green)
UP button
3 1/2-digit LED
Enter the set value of the
pressure to perform switch
output.
Automatically sets the pressure
for the adsorption confirmation
or
confirmation.
pressure setting
Manual
supply
preset
Auto
Digital Pressure Switch
pressure
OUT1
High Precision,
SET
Adjusts the zero point of the
atmospheric pressure.
Allows fine-tuning of the
data set automatically by
auto preset.
OUT2
kPa
pressure setting
Zero clear
Manual
Series
Displays OUT2 output condition.
When it is ON, the LED is
illuminated.
Switches the mode and set value.
Switches to each mode and fixes
the set value.
LED (Red)
DOWN button
SET button
ZSE40/ISE40
Mode is not switched, even if
the button is pressed during
operation.
Measured
displayed and the switch
operation begins.
Normal operation
Key lock
mode
pressure
16-2-19
is
ZSE„
ISE„
PSE
Z
PS
Z
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Data
I
I
SE3
SE
1
2