ZSE40-T1-62 SMC Corporation of America, ZSE40-T1-62 Datasheet

no-image

ZSE40-T1-62

Manufacturer Part Number
ZSE40-T1-62
Description
SENSOR VACUUM 101.3KPA PNP/ ANLG
Manufacturer
SMC Corporation of America
Series
ZSE40r
Datasheet

Specifications of ZSE40-T1-62

Pressure Type
Vacuum
Operating Pressure
-14.65 ~ 1.45 PSI, -101 ~ +10 kPa
Port Size
Female, 1/8" (3.175mm) NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable with Connector
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1011
For vacuum/compound pressure
∗ Option
01: R 1/8 (With M5 female threads)
T1: NPT 1/8 (With M5 female threads)
Wall mount
∗ C4: With ø4 One-touch fitting
∗ C6: With ø6 One-touch fitting
For positive pressure
Nil
F
Nil
10.0 to –101.3 kPa
–100.0 to 100.0 kPa
–0.100 to 1.000 MPa
R 1/8, NPT 1/8
M5 x 0.8 female threads
ø4, ø6
One-touch fitting
Note
When equipped with auto shift function, the following ranges can be set.
∗ Option
22
30 ∗
62 ∗
70 ∗
–100.0 to 100.0 kPa
Set pressure range
Set pressure range
For vacuum pressure
For compound pressure
Set pressure range
10.0 to –101.3 kPa
–0.1 to 1.000 MPa
∗ M5: M5 x 0.8 (Female threads)
For positive pressure
W1: Rc 1/8
Reverse pressure
two directions
Wall mount
NPN open collector 2 outputs + analog output
NPN open collector 2 outputs + auto shift input
PNP open collector 2 outputs + analog output
PNP open collector 2 outputs + auto shift input
ZSE40
ISE40
Piping specifications
Digital Pressure Switch
Input/Output specifications
M5 x 0.8
How to Order
Rc 1/8
Rc 1/8
–1.000 to 1.000 MPa
–100.0 to 100.0 kPa
–101.3 to 101.3 kPa
High Precision,
Setting range
01
01
22
22
Series
Lead wire length
Nil
L
0.6 m
3 m
Note 1) This will no longer be sold for use in
Note 2) Fixed unit
Unit specifications
Nil
M
ZSE40/ISE40
∗ When optional parts only are
required, order with the part
numbers inside ( ).
Option
Japan after the new Weight and
Measure Act is implemented
(October,1999).
For vacuum/compound pressure: kPa
For positive pressure: MPa
Nil
With unit switching function
A
B
E
F
None
Bracket A
Bracket B
Panel mount
Panel mount
+ Front protective cover
SI unit only
Note 2)
(ZS-24-C)
(ZS-22-A)
(ZS-24-A)
(ZS-24-B)
16-2-17
Note1)
ZSE„
ISE„
PSE
Z
PS
Z
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Data
I
I
SE3
SE
1
2

Related parts for ZSE40-T1-62

ZSE40-T1-62 Summary of contents

Page 1

... Digital Pressure Switch How to Order 1 0.8 Input/Output specifications Setting range Lead wire length –100.0 to 100.0 kPa –101.3 to 101.3 kPa –1.000 to 1.000 MPa ZSE40/ISE40 Option Nil None Bracket A (ZS-24-A) A Bracket B (ZS-24-B) B Panel mount (ZS-22-A) E Panel mount (ZS-24-C) + Front protective cover F ∗ ...

Page 2

... Note 2) For ZSE40 (F)/ISE40-„ Note 3) For ZSE40 (F)/ISE40-„- 70 Note 4) For ZSE40F (compound pressure) with “psi” indication, this is 0.03 to 0.04 psi. Note 5) For ZSE40F (compound pressure) with “psi” indication, zero clear is in the range of ±0.01 psi. Example of Internal Circuit and Wiring ZSE40(F) ISE40-„ ...

Page 3

... Auto Manual preset pressure setting Allows fine-tuning of the data set automatically by supply pressure auto preset. ZSE40/ISE40 Series LED (Red) Displays OUT2 output condition. When it is ON, the LED is illuminated. DOWN button Switches the mode and set value. SET button Switches to each mode and fixes the set value ...

Page 4

... Display of setting auto shift SET “SET” button. Press the “SET” button to complete the setting. ∗ Only for ZSE40(F)/ISE40-„-30/70(L)-M, displays the input mode “ ” and the compensation value alternately. If auto shift input is not complete, zero is displayed. ...

Page 5

... Unit Set It's only subject to ZSE40(F)/ISE40-„-„(L). Unit selection Set the unit by either button or button. : kPa or MPa, : kgf/ bar, : psi, : inHg, : mmHg SET Press “SET” button. OUT1: Selection of the output mode Auto Preset (For adsorption confirmation) 1. Auto preset mode ...

Page 6

... ZSE40/ISE40 Series Calibration Procedures Auto Preset (In the case of confirming the supply pressure) 1. Auto preset mode Select the Auto preset mode in the initial setting mode and press the “SET” button until “ ” is displayed. ON point (C, C1) Hysteresis (3 digits) OFF ON point = C, C1 OFF point = C-3 digits, C1-3 digits (1 digit is the minimum setting unit ...

Page 7

... For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” on page 16-2-24 for details.) 2-M4 x 0.7 thread depth 4 ø3.5 ∗ For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” on page 16-2-24 for details.) ZSE40/ISE40 20 ZSE„ ISE„ PSE Z SE3 I ...

Page 8

... ZSE40/ISE40 Series Dimensions C4 ZSE40 ( F ) /ISE40– 32 MPa OUT1 OUT2 SET Atmospheric release port 7.8 12 One-touch fitting ø4, ø6 ∗ For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” for details.) Caution 1. Immediately after supplying power, there is drift of about ±0.5% F.S. When used with very low pressure, allow the unit to warm up for about minutes ...