SRI512-A3S/1GE STMicroelectronics, SRI512-A3S/1GE Datasheet - Page 35

IC MEMORY 13.56MHZ EEPRM ADH ANT

SRI512-A3S/1GE

Manufacturer Part Number
SRI512-A3S/1GE
Description
IC MEMORY 13.56MHZ EEPRM ADH ANT
Manufacturer
STMicroelectronics
Series
SRI512r
Datasheets

Specifications of SRI512-A3S/1GE

Rf Type
Read / Write
Frequency
13.56MHz
Features
ISO14443-B
Package / Case
38mm x 38mm
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5535-2
SRI512
8.7
READ_BLOCK(Addr) command
Command Code = 08h
On receiving the READ_BLOCK command, the SRI512 reads the desired block and returns
the 4 data Bytes contained in the block. Data Bytes are transmitted with the Least
Significant Byte first and each byte is transmitted with the least significant bit first.
The address byte gives access to the 16 blocks of the SRI512 (addresses 0 to 15).
READ_BLOCK commands issued with a block address above 15 will not be interpreted and
the SRI512 will not return any response, except for the System area located at address 255.
The SRI512 must have received a SELECT() command and be switched to SELECTED
state before any READ_BLOCK() command can be accepted. All READ_BLOCK()
commands sent to the SRI512 before a SELECT() command is issued are ignored.
Figure 41. READ_BLOCK request format
Request parameter:
Figure 42. READ_BLOCK response format
Response parameters:
Figure 43. READ_BLOCK frame exchange between Reader and SRI512
Reader
SRI512
SOF
ADDRESS: block addresses from 0 to 15, or 255
DATA 1: Less significant data Byte
DATA 2: Data Byte
DATA 3: Data Byte
DATA 4: Most significant data Byte
SOF
SOF
08h
DATA 1
8 bIts
READ_BLOCK
ADDR
08h
CRC L CRC H EOF
DATA 2
8 bIts
ADDRESS
8 bIts
DATA 3
8 bIts
<-t 0 -> <-t 1 ->
8 bits
DATA 4
SOF DATA
CRC L
8 bIts
1
DATA
2
CRC L
8 bits
CRC H
DATA
8 bits
3
DATA
SRI512 commands
4
CRC H
8 bIts
CRC L CRC H EOF
EOF
AI07684
AI10948
EOF
AI07685
35/50