SX1231IMLTRT Semtech, SX1231IMLTRT Datasheet - Page 17

IC 433/868/915MHZ TXRX 24-QFN

SX1231IMLTRT

Manufacturer Part Number
SX1231IMLTRT
Description
IC 433/868/915MHZ TXRX 24-QFN
Manufacturer
Semtech
Datasheets

Specifications of SX1231IMLTRT

Frequency
433MHz, 868MHz, 915MHz
Data Rate - Maximum
300kbps
Modulation Or Protocol
FSK, GFSK, GMSK, MSK, OOK
Applications
AMR, Home Automation, Security
Power - Output
13dBm
Sensitivity
-118dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
16mA
Current - Transmitting
95mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
24-QFN
Transmitting Current
95mA
Data Rate
300Kbps
Rf Ic Case Style
QFN
No. Of Pins
24
Supply Voltage Range
1.8V To 3.6V
Operating Temperature Range
-40°C To +85°C
Receiving Current
16mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Compliant
Other names
SX1231IMLTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1231IMLTRT
Manufacturer:
ATMEL
Quantity:
1 200
Part Number:
SX1231IMLTRT
Manufacturer:
SEMTECHCORPORATION
Quantity:
20 000
3.3.2. CLKOUT Output
The reference frequency, or a fraction of it, can be provided on DIO5 (pin 12) by modifying bits ClkOut in RegDioMapping2.
Two typical applications of the CLKOUT output include:
Note
3.3.3. PLL Architecture
The frequency synthesizer generating the LO frequency for both the receiver and the transmitter is a fractional-N sigma-
delta PLL. The PLL incorporates a third order loop capable of fast auto-calibration, and it has a fast switching-time. The
VCO and the loop filter are both fully integrated, removing the need for an external tight-tolerance, high-Q inductor in the
VCO tank circuit.
3.3.3.1. VCO
The VCO runs at 2, 4 or 6 times the RF frequency (respectively in the 915, 434 and 315 MHz bands) to reduce any LO
leakage in receiver mode, to improve the quadrature precision of the receiver, and to reduce the pulling effects on the VCO
during transmission.
The VCO calibration is fully automated. A coarse adjustment is carried out at power on reset, and a fine tuning is
performed each time the SX1231 PLL is activated. Automatic calibration times are fully transparent to the end-user, as their
processing time is included in the TS_TE and TS_RE specifications.
3.3.3.2. PLL Bandwidth
The bandwidth of the SX1231 Fractional-N PLL is wide enough to allow for:
3.3.3.3. Carrier Frequency and Resolution
The SX1231 PLL embeds a 19-bit sigma-delta modulator and its frequency resolution, constant over the whole frequency
range, and is given by:
The carrier frequency is programmed through RegFrf, split across addresses 0x07 to 0x09:
Note
Rev 3 - April 2010
ADVANCED COMMUNICATIONS & SENSING
To provide a clock output for a companion processor, thus saving the cost of an additional oscillator. CLKOUT can be
made available in any operation mode except Sleep mode and is automatically enabled at power on reset.
To provide an oscillator reference output. Measurement of the CLKOUT signal enables simple software trimming of the
initial crystal tolerance.
High speed FSK modulation, up to 300 kb/s, inside the PLL bandwidth
Very fast PLL lock times, enabling both short startup and fast hop times required for frequency agile applications
to minimize the current consumption of the SX1231, please ensure that the CLKOUT signal is disabled when not
required.
The Frf setting is split across 3 bytes. A change in the center frequency will only be taken into account when the
least significant byte FrfLsb in RegFrfLsb is written. This allows for more complex modulation schemes such as m-
ary FSK, where frequency modulation is achieved by changing the programmed RF frequency.
F
RF
F
=
STEP
F
Page 17
STEP
=
F
--------------- -
×
XOSC
2
Frf 23 0
19
( , )
DATASHEET
www.semtech.com
SX1231

Related parts for SX1231IMLTRT