MTCMR-G-F4 Multi-Tech Systems, MTCMR-G-F4 Datasheet - Page 111

no-image

MTCMR-G-F4

Manufacturer Part Number
MTCMR-G-F4
Description
MODEM GPRS QUAD BAND GSM GLOBAL
Manufacturer
Multi-Tech Systems
Series
MultiModem® iCellr
Datasheets

Specifications of MTCMR-G-F4

Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz
Applications
General Purpose
Interface
RS-232, USB
Function
Transceiver, Modem
Data Rate - Maximum
115.2kbps
Modulation Or Protocol
GSM, GPRS
Voltage - Supply
9 V ~ 32 V
Package / Case
Module with Case
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Power - Output
-
Sensitivity
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
881-1151
MTCMR-G-F4
Analog Digital Converter Measurements +ADC
Multi-Tech Systems, Inc. GPRS AT Commands Reference Guide (Document Number S000293J)
Description:
Values:
Syntax:
Additional Notes:
This command gets the (DC level * 1024) of ADC A and ADC B, and possibly ADC C. These voltages
are coded on 10 bits.
<n>
<ADCValA>
<ADCValB>
<ADCValC>
<ADCValD>
Command syntax: AT+ADC<n>
Response syntax: +ADC: <ADCValA>,<ADCValB>[,<ADCValC>][,<ADCValD>]
Command
AT+ADC=?
Note: Ask for the list of possible values
AT+ADC=0
Note: Select 2 converters (mode 0)
AT+ADC?
Note: Ask for the current values of
converters in mode 0
AT+ADC=1
Note: Select extended mode (mode 1)
0
1
ADC A value, coded on 10 bits. The value returned includes the resistor bridge. Values are updated
every 10 seconds. Displayed on modes 0 and 1.
ADC B value, coded on 10 bits. Displayed on modes 0 and 1.
ADC C value, coded on 10 bits. Displayed on mode 1 only.
ADC D value, coded on 10 bits. Displayed on mode 1 only.
The AT+WIND? command is supported and indicates the <allowed bit flows>.
AT+WIND settings are automatically stored in non volatile memory (EEPROM). This means the &W
command does not need to be used and the selected flows are always activated after boot.
Default value is 0: no flow activated, no indication.
AT+WIND=? gives the possible value range (0-4095)
The unsolicited response will then be:
Or for event 10:
Or for event 11:
Or for event 15 (NITZ indication):
Select 2 converters
Select 3 converters
+WIND: <event> [,<idx>]
<idx>: Call identifier, defined in +CLCC command.
+WIND: <event>,<phonebook>,<status>,…,<phonebook>,<status>
+WIND: <event>,[“<checksum of SM>”],[“<checksum of FD>”],[“<checksum of
ON>”],[“<checksum of SN>”] ,[“<checksum of EN>”],[“<checksum of LD>”]
+WIND: <event>[,1,"Full name>"][,2,"<Short name>"][,3,"<Local time zone>"][,4,"<Universal
time and local time zone>"][,5,"<LSA identity>"][,6,"<Daylight Saving Time>"]
Possible responses
+ADC: (0-1)
Note: possible values 0 or 1
OK
Note: 2 converters mode selected
+ADC: 500,412
OK
Note: ADC A, ADC B on 10 bits
OK
Note: Extended mode selected
Chapter 13 – Specific AT Commands
111

Related parts for MTCMR-G-F4