1. Install the RFIC Design Assistant utility program from the kit CD. If you are using
2. If installed, remove the 9 volt batteries from the board sets. Install the antennas
3. Connect one of the board sets to the PC. Turn on the board set by sliding the
4. Start the RFIC Design Assistant utility program as shown in Figure 7. Select the
5. Select the TRC103 from the TRC drop-down menu as shown in Figure 8. This
6. Select the Main Menu tab and click on the Read Configuration button. A hex
the USB interface, install the virtual COM port drivers. Refer to the USB Virtual
COM Ports section of the RFIC Design Assistant User’s Guide on the CD for
driver installation details.
as needed and then connect a 4.5 volt wall-plug power supply to each board set.
Power switch on the interface board to the ON position. All LED’s on the radio
board will flash and the MODE LED will be green.
COM port or virtual COM port assigned to the board set from the drop-down
menu at the top of the utility program screen. The COM port can be determined
from Windows® as follows: Start > Settings > Control Panel > System >
Hardware > Device Manager > Ports (COM & LPT).
will launch the TRC103 multi-tab dialog window as shown in Figure 9
dump of the current TRC103 configuration parameters should appear in the text
box above the button as shown in Figure 9. This confirms the development board
set is communicating with the utility program. Test the other development kit
board set in the same manner. The development kit is now ready to use.
Figure 6 - Initial Testing Using Range Test Function