XTIB-R Digi International/Maxstream, XTIB-R Datasheet - Page 68

no-image

XTIB-R

Manufacturer Part Number
XTIB-R
Description
BOARD INTERFACE 1W RS232/485
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTIB-R

Accessory Type
Interface Board
For Use With/related Products
XTend Radios
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
Q2172356
9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04]
RS-485/422 Connection Guidelines
Figure B‐24.  XTend Module Assembly in an RS‐422 environment
The RS-485/422 protocol provides a solution for wired communications that can tolerate high
noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as
4000 feet (1200 m). RS-232 signals are suitable for cable distances up to 100 feet (30.5 m).
RS-485 offers multi-drop capability in which up to 32 nodes can be connected. The RS-422 proto-
col is used for point-to-point communications.
Suggestions for integrating the XTend RF Module with the RS-485/422 protocol:
1.
2.
3.
4.
© 2007 MaxStream, Inc.
When using Ethernet twisted pair cabling: Select wires so that T+ and T- are connected to
each wire in a twisted pair. Likewise, select wires so that R+ and R- are connected to a
twisted pair. (For example, tie the green and white/green wires to T+ and T-.)
For straight-through Ethernet cable (not cross-over cable) - The following wiring pattern
works well: Pin3 to T+, Pin4 to R+, Pin5 to R-, Pin6 to T-
Note that the connecting cable only requires 4 wires (even though there are 8 wires).
When using phone cabling (RJ-11) - Pin2 in the cable maps to Pin3 on opposite end of
cable and Pin1 maps to Pin4 respectively.