XTIB-R Digi International/Maxstream, XTIB-R Datasheet - Page 21

no-image

XTIB-R

Manufacturer Part Number
XTIB-R
Description
BOARD INTERFACE 1W RS232/485
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTIB-R

Accessory Type
Interface Board
For Use With/related Products
XTend Radios
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
Q2172356
Table 3‐01. XTend Commands (The RF modules expect numerical values in hexadecimal. Hexadecimal values are designated by a “0x” 
* Firmware version in which command and parameter options were first supported
9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04]
AT
Command
PE v2.x20*
PK
PL
PW
RB
RC
RE
RM
RN
RO
RP
RR
RT
SB
SH
SL
SM
ST
TP
TR
TT
TX
VL
VR
WA
WN
WR
WS
prefix. Decimal equivalents are designated by a “d” suffix.)
Binary
Command
0x46 (70d)
0x29 (41d)
0x3A (58d)
0x1D (29d)
0x20 (32d)
--
0x0E (14d)
--
0x19 (25d)
0x21 (33d)
0x22 (34d)
0x18 (24d)
0x16 (22d)
0x37 (55d)
0x25 (37d)
0x26 (38d)
0x01 (1d)
0x02 (2d)
0x38 (56d)
0x1B (27d)
0x1A (26d)
0x3F (63d)
--
0x14 (20d)
--
--
0x08 (8d)
--
AT Command Name
Polling End Address
Maximum RF Packet Size
TX Power Level
Pin Wake-up
Packetization Threshold
Ambient Power - Single Channel
Restore Defaults
Ambient Power - All Channels
Delay Slots
Packetization Timeout
RSSI PWM Timer
Retries
GPI1 Configuration
Stop Bits
Serial Number High
Serial Number Low
Sleep Mode
Time before Sleep
Board Temperature
Delivery Failure Count
Streaming Limit
Transmit Only
Firmware Version - verbose
Firmware Version
Active Warning Numbers
Warning Data
Write
Sticky Warning Numbers
© 2007 MaxStream, Inc.
Parameter Range
0 - 0xFFFF
1 - 0x800 [Bytes]
0 - 4
0 - 1
1 - Current value of PK
0 - 0x31 [dBm, read-only]
--
No parameter - 0x7D0
0 - 0xFF [slots]
0 - 0xFFFF [x UART character time]
0 - 0xFF [x 100 msec]
0 - 0xFF
0 - 2
0 - 1
0 - 0xFFFF [read-only]
0 - 0xFFFF [read-only]
0 - 8 (3 is reserved)
(ATAT+3) - 0x7FFF [x 100 msec]
0 - 0x7F [read-only]
0 - 0xFFFF [read-only]
0 - 0xFFFF [0 = disabled]
0 - 1
Returns string
0 - 0xFFFF [read-only]
Returns string
Returns string
--
Returns string
Command
Category
Networking & Security
RF Interfacing
RF Interfacing
Sleep (Low Power)
Serial Interfacing
Diagnostics
(Special)
Diagnostics
Networking & Security
Serial Interfacing
Diagnostics
Networking & Security
Serial Interfacing
Serial Interfacing
Diagnostics
Diagnostics
Sleep (Low Power)
Sleep (Low Power)
Diagnostics
Diagnostics
Networking & Security
RF Interfacing
Diagnostics
Diagnostics
Diagnostics
Diagnostics
(Special)
Diagnostics
Chapter 3 ‐ RF Module Configuration
# Bytes
Returned
2
2
1
1
2
1
--
2
1
2
1
1
1
1
2
2
1
2
1
2
2
1
--
2
--
--
--
--
Factory
Default
0
varies
4 (1 Watt)
0
0x800 (2048d)
--
--
--
0
3
0x20 (32d)
0x0A (10d)
0
0
varies
varies
0
0x64 (100d)
--
0
0
0
--
--
--
--
--
--
     21

Related parts for XTIB-R