XTIB-R Digi International/Maxstream, XTIB-R Datasheet - Page 36

no-image

XTIB-R

Manufacturer Part Number
XTIB-R
Description
BOARD INTERFACE 1W RS232/485
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XTIB-R

Accessory Type
Interface Board
For Use With/related Products
XTend Radios
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
Q2172356
9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04]
RT (GPI1 Configuration) Command
SB (Stop Bits) Command
SH (Serial Number High) Command
SL (Serial Number Low) Command
<Serial Interfacing> The RT command is used to
set/read the behavior of the GPI1 pin (pin 10) of
the OEM RF Module. The pin can be configured to
enable binary programming or RTS flow control.
<Serial Interfacing> The SB Command is used to
set/read the number of stop bits in the data
packet.
<Diagnostics> SH Command is used to set/read
the serial number high word of the RF module.
<Diagnostics> SL Command is used to set/read
the serial number low word of the RF module.
© 2007 MaxStream, Inc.
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range: 0 - 2
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATSB
Binary Command: 0x37 (55 decimal)
Parameter Range: 0 - 1
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range (read-only): 0 - 0xFFFF
Default Parameter Value: varies
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
AT Command: ATSL
Binary Command: 0x26 (38 decimal)
Parameter Range (read-only): 0 - 0xFFFF
Default Parameter Value: varies
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
l
d
Parameter
Parameter
Chapter 3 ‐ RF Module Configuration
0
1
2
0
1
d
Enable RTS Flow Control
( l
Configuration
Configuration
Enable Binary
Programming
2 stop bits
1 stop bit
Disabled
d )
     36