Other names
Q2172356
9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04]
RS-485 (4-wire) & RS-422 Operation
DIP Switch Settings and Serial Port Connections
Wiring Diagrams
Figure B‐22.
RS‐485 (4‐wire)& RS‐422 w/ Termination (optional)
Termination is the 120 Ω resistor between T+ and T‐.
DIP Switch settings are read and applied only while powering‐on.
Figure B‐20.
RS‐485 (4‐wire) & RS‐422 
DIP Switch Settings
Note: Refer to Figures B-09 and B-10 for RJ-45 connector pin designations used in
RS-485/422 environments.
Table B‐06. RS‐485/422 (4‐wire) Signals and their implementations on the XTend Module Assembly
Figure B‐23.  XTend Module Assembly in an RS‐485 (4‐wire) environment
© 2007 MaxStream, Inc.
DB-9 Pin
1, 4, 6
2
3
5
7
8
9
RS-485/422
R+ (RB)
R- (RA)
T+ (TB)
Name
T- (TA)
PWR
GND
Transmit Negative
Receive Negative
Transmit Positive
Receive Positive
Description
Signal Ground
Data Line
Data Line
Data Line
Data Line
Power
Figure B‐21.
Pins used on the female RS‐232 (DB‐9) 
Serial Connector 
not used
Serial data received by the XTend Module Assembly
Serial data received by the XTend Module Assembly
Serial data sent from the XTend Module Assembly
Serial data sent from the XTend Module Assembly
Optional power input that is connected internally
to the front power connector
Implementation