XBIB-R Digi International/Maxstream, XBIB-R Datasheet - Page 27

no-image

XBIB-R

Manufacturer Part Number
XBIB-R
Description
BOARD RS232 ZIGBEE MOD PRO
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XBIB-R

Design Resources
XBIB-R Schematic
Accessory Type
Interface Board
For Use With/related Products
XBee and XBee Pro Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 3‐02. XBee/XBee‐PRO Commands ‐ Networking & Security (Sub‐categories designated within {brackets})
XBee/XBee‐PRO™ OEM RF Modules ‐ 802.15.4 ‐ v1.xAx [2007.05.031]
AT
Command
NI ( v1.x80*)
ND ( v1.x80*)
NT ( v1.xA0*)
DN ( v1.x80*)
CE ( v1.x80*)
SC ( v1.x80*)
SD ( v1.x80*)
A1 ( v1.x80*)
Command
Category
Networking
{Identification}
Networking
{Identification}
Networking
{Identification}
Networking
{Identification}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Name and Description
Node Identifier. Stores a string identifier. The register only accepts printable ASCII
data. A string can not start with a space. Carriage return ends command. Command will
automatically end when maximum bytes for the string have been entered. This string is
returned as part of the ND (Node Discover) command. This identifier is also used with
the DN (Destination Node) command.
Node Discover. Discovers and reports all RF modules found. The following information
is reported for each module discovered (the example cites use of Transparent operation
(AT command format) - refer to the long ND command description regarding differences
between Transparent and API operation).
The amount of time the module allows for responses is determined by the NT
parameter. In Transparent operation, command completion is designated by a <CR>
(carriage return). ND also accepts a Node Identifier as a parameter. In this case, only a
module matching the supplied identifier will respond.
Node Discover Time. Set/Read the amount of time a node will wait for responses from
other nodes when using the ND (Node Discover) command.
Destination Node. Resolves an NI (Node Identifier) string to a physical address. The
following events occur upon successful command execution:
If there is no response from a module within 200 msec or a parameter is not specified
(left blank), the command is terminated and an “ERROR” message is returned.
Coordinator Enable. Set/Read the coordinator setting.
Scan Channels. Set/Read list of channels to scan for all Active and Energy Scans as a
bitfield. This affects scans initiated in command mode (AS, ED) and during End Device
Association and Coordinator startup:
Scan Duration. Set/Read the scan duration exponent.
End Device - Duration of Active Scan during Association. On beacon system, set SD =
BE of coordinator. SD must be set at least to the highest BE parameter of any
Beaconing Coordinator with which an End Device or Coordinator wish to discover.
Coordinator - If ‘ReassignPANID’ option is set on Coordinator [refer to A2 parameter],
SD determines the length of time the Coordinator will scan channels to locate existing
PANs. If ‘ReassignChannel’ option is set, SD determines how long the Coordinator will
perform an Energy Scan to determine which channel it will operate on.
‘Scan Time’ is measured as (# of channels to scan] * (2 ^ SD) * 15.36ms). The number
of channels to scan is set by the SC command. The XBee can scan up to 16 channels
(SC = 0xFFFF). The XBee PRO can scan up to 13 channels (SC = 0x3FFE).
Example: The values below show results for a 13 channel scan:
End Device Association. Set/Read End Device association options.
bit 0 - ReassignPanID
bit 1 - ReassignChannel
bit 2 - AutoAssociate
Note: This bit is used only for Non-Beacon systems. End Devices in Beacon-enabled
system must always associate to a Coordinator
bit 3 - PollCoordOnPinWake
bits 4 - 7 are reserved
© 2007 MaxStream, Inc.
MY<CR>
SH<CR>
SL<CR>
DB<CR>
NI<CR><CR>
1. DL and DH are set to the address of the module with the matching Node Identifier.
2. “OK” is returned.
3. RF module automatically exits AT Command Mode
bit 0 - 0x0B
bit 1 - 0x0C
bit 2 - 0x0D
bit 3 - 0x0E
If SD = 0, time = 0.18 sec SD = 8, time = 47.19 sec
SD = 2, time = 0.74 sec
SD = 4, time = 2.95 sec
SD = 6, time = 11.80 sec
0 - Will only associate with Coordinator operating on PAN ID that matches module ID
1 - May associate with Coordinator operating on any PAN ID
0 - Will only associate with Coordinator operating on matching CH Channel setting
1 - May associate with Coordinator operating on any Channel
0 - Device will not attempt Association
1 - Device attempts Association until success
0 - Pin Wake will not poll the Coordinator for indirect (pending) data
1 - Pin Wake will send Poll Request to Coordinator to extract any pending data
bit 4 - 0x0F
bit 5 - 0x10
bit 6 - 0x11
bit 7 - 0x12
SD = 10, time = 3.15 min
SD = 12, time = 12.58 min
SD = 14, time = 50.33 min
bit 8 - 0x13
bit 9 - 0x14
bit 10 - 0x15
bit 11 - 0x16
bit12 - 0x17
bit13 - 0x18
bit14 - 0x19
bit 15 - 0x1A
Chapter 3 ‐ RF Module Configuration
Parameter Range
optional 20-character NI value
0x01 - 0xFC
0 - 1
0 - 0xFFFF [bitfield]
(bits 0, 14, 15 not allowed on
the XBee-PRO)
0-0x0F [exponent]
0 - 0x0F [bitfield]
20-character ASCII string
20-character ASCII string
0 = End Device
1 = Coordinator
Default
-
0x19
-
0
0x1FFE
(all XBee-
PRO
Channels)
4
0
     27