E3X-NH11 Omron, E3X-NH11 Datasheet - Page 9

SENSOR PHOTO AMP FIBEROPTIC NPN

E3X-NH11

Manufacturer Part Number
E3X-NH11
Description
SENSOR PHOTO AMP FIBEROPTIC NPN
Manufacturer
Omron
Type
High Precision Fiber Optic Amplifierr
Series
E3X-NHr
Datasheets

Specifications of E3X-NH11

Output Type
NPN
Amplifier Type
General Purpose
Voltage - Supply
12 V ~ 24 V
Current - Supply
75mA
Mounting Type
DIN Rail
Features
Three mode for optimal sensing
Light Source
Red LED
Connection
Pre-leaded
Output Configuration
NPN
Sensor Output
NPN
Switch Terminals
Cable
Supply Voltage Min
12V
Peak Reflow Compatible (260 C)
No
Sensor Input
Fiber Optic
Supply Voltage Max
24V
Leaded Process Compatible
No
Rohs Compliant
No
Fiber Optic Sensor Type
General Purpose
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS compliant by exemption
Other names
E3XNH11
Z1110

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NH11
Manufacturer:
OMRON
Quantity:
475
E3X-NH
10
One-point Teach Mode
Diffuse (Light-ON) Fiber Unit
1. Press the SET button without the target in the sensing
Note:
2. Detecting the first object in RUN/ADJ mode.
Farther
Closer
Ideal if it is impossible to perform teaching with the target
fixed in the sensing area.
Ideal for high-precision positioning.
Ideal for detection of bright or dark objects.
area.
Set the threshold to the value that is ±6% of the incident
level.
Farther
Light
Closer
Light
If the target is not present at the time of teaching, the
threshold cannot be set to the position corresponding
to -6% of the incident level. The sensitivity will then be
set to maximum automatically when in RUN mode.
Target
Threshold
Threshold
6%
6%
Threshold
6%
Incident
level
indicator
The number of indicators lit depends on
the position of the target. The threshold
position of the target is set to 7.
Incident level without a fixed background
or target.
Threshold
indicator
18%
18%
Tuning
range
Through-beam (Dark-ON) Fiber Unit
1. Press the SET button without target in the sensing area.
2. Detecting the first object in RUN/ADJ mode.
Farther
Set the threshold to the value that is ±6% of the incident
level.
Closer
Farther
Light
Closer
Light
Threshold
Threshold
Target
6%
6%
Threshold
6%
Incident
level
indicator
Incident level without a fixed
background or target.
The number of indicators lit depends on
the position of the target. The threshold
position of the target is set to 7.
Threshold
indicator
18%
18%
Tuning
range
E3X-NH