E3X-NH21 Omron, E3X-NH21 Datasheet - Page 16

SENSOR PHOTO AMP FIBEROPTC W/TMR

E3X-NH21

Manufacturer Part Number
E3X-NH21
Description
SENSOR PHOTO AMP FIBEROPTC W/TMR
Manufacturer
Omron
Series
E3X-NHr
Type
High Precision Fiber Optic Amplifierr
Datasheet

Specifications of E3X-NH21

Amplifier Type
Timer Function
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
75mA
Mounting Type
DIN Rail
Features
Three mode for optimal sensing
Light Source
Red LED
Connection
Pre-leaded
Output Configuration
NPN
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption, Lead free / RoHS Compliant
Other names
E3XNH21
Z1112
Precautions
J AVOID DAMAGE TO THE E3X-NH
J REFLECTOR
Precautions for Using the E39-R3 Reflector
Use detergent, etc., to remove any dust or oil from the surfaces
where tape is applied. Adhesive tape will not be attached
properly if oil or dust remains on the surface.
The E39-R3 cannot be used in places where it is exposed to oil
or chemicals.
J MUTUAL INTERFERENCE PROTECTION
Perform two-point teaching if two to three Fiber Units are closely
mounted together. The mutual interference feature will guard
against false triggering.
J EEPROM WRITING ERROR
Write errors may result at the time of teaching due to power
failure or static noise. If any of these occur, re-teach the
amplifier.
E3X-NH
Cat. No. CEDSAX4
The E3X-NH is not a safety component for ensuring the
safety of people as defined in EC Directive 91/368/EEC, or
as covered by separate European standards or by any other
regulations or standards.
1-800-55-OMRON
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
Do not impose any voltage exceeding the rated voltage on
the E3X-NH.
Do not impose 100 VAC or more on models that operate with
DC.
When supplying power to the E3X-NH, make sure that the
polarity of the power is correct.
Do not short-circuit the load connected to the E3X-NH.
The load must be connected to the E3X-NH in operation.
SENSOR
!
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
WARNING
11/01
OMRON ON- -LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
Specifications subject to change without notice.
J SENSING A MINUTE OBJECT
This data sheet shows typical examples for detecting minute
objects. These typical examples are for reference use only,
because these example operations were tested on Units sampled
at random from a lot and the values described are average
values. Do not assume that all Units ensure such operations.
J WHEN THE POWER IS OFF
The moment power is turned off, the E3X-NH may output a pulse
signal which could affect the operation of the devices connected
to it. This will occur more often if power is supplied to the
E3X-NH from an external power supply, thus affecting the
connected timer or counter. We recommend using a separate
power supply to avoid a false signal.
For extending the cable, use wire with 0.3 mm
length of the cable should be a maximum of 100 m.
J POWER SUPPLY
If a standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, or the Amplifier can malfunction due to the switching
noise of the power supply.
The supplied voltage must be within the rated voltage range.
Unregulated full- or half-wave rectifiers must not be used as
power supplies.
J WIRING
Never wire the Amplifier within the same conduit with power
lines. Doing so will cause induction between the lines, possibly
resulting in faulty operation or damage. Always wire the Amplifier
in a separate, dedicated conduit.
Power line
OMRON CANADA, INC.
416-286-6465
885 Milner Avenue
Scarborough, Ontario M1B 5V8
2
min. The total
Printed in U.S.A.
E3X-NH
17
17

Related parts for E3X-NH21