E3X-NH21 Omron, E3X-NH21 Datasheet - Page 15

SENSOR PHOTO AMP FIBEROPTC W/TMR

E3X-NH21

Manufacturer Part Number
E3X-NH21
Description
SENSOR PHOTO AMP FIBEROPTC W/TMR
Manufacturer
Omron
Series
E3X-NHr
Type
High Precision Fiber Optic Amplifierr
Datasheet

Specifications of E3X-NH21

Amplifier Type
Timer Function
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
75mA
Mounting Type
DIN Rail
Features
Three mode for optimal sensing
Light Source
Red LED
Connection
Pre-leaded
Output Configuration
NPN
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption, Lead free / RoHS Compliant
Other names
E3XNH21
Z1112
E3X-NH
When Side-Mounting
Insert the fiber into the Amplifier up to the insertion mark. Proper
fiber performance will not be achieved unless the fiber is inserted
all the way to the insertion mark. (This method is applicable to
standard, 2.2-mm-diameter fibers only.)
The cutting holes cannot be used twice. If the same hole is used
twice, the cutting face of the fiber will be rough and the sensing
distance will be reduced. Always use an unused hole.
Use either one of the two holes on the right (refer to the following
figure) to cut a thin fiber as follows:
16
When side-mounting:
Attach the mounting bracket on the Amplifier first, and secure
the amplifier with M3 screws and washers. The diameter of
the washers should be a maximum of 6 mm.
1. An attachment is temporarily fitted to a thin fiber before
2. Secure the attachment after adjusting the position of it in the
3. Insert the fiber into the E39-F4 to cut.
shipment.
direction indicated by the arrow.
Washers
(6 dia. max.)
12.6
Temporarily fitted
Three holes for
standard fiber
(2.2-mm dia.)
2.2-dia.
Insertion mark
Thin fiber attachment (E39-F9)
Cutter E39-F4
Two holes for
thin fiber
Note:
Connection
Do not pull or press the Fiber Units. The Fiber Units have a
withstand force of 9.8 N (1 kgf) or 29.4 N (3 kgf) (pay utmost
attention because the fibers are thin).
Do not bend the Fiber Units beyond the permissible bending
radius.
Do not bend the edge of the Fiber Units (excluding the E32-TjR
and E32-DjR).
Do not apply excess force on the Fiber Units.
The Fiber Head could be break by excessive vibration. To
prevent this, the following is effective:
Turning the Power ON
When the power is turned ON, the operation indicator will be ON
momentarily. Note that this will not have an effect on performance
since no control output will be generated.
When the power is turned ON, the operation indicator will be ON
momentarily. Note that this will not have an effect on performance
since no control output will be generated.
Perform two-point teaching if two to three Fiber Units are closely
mounted together, at which time supply power only to the Unit in
teaching operation in turn or block the emitters of the Fiber Units
not in teaching operation.
Correct
Incorrect
4. Finished state (proper cutting state)
Insert the fiber in the direction indicated by the arrow.
Correct
Incorrect
A one-turn loop can
absorb vibrations.
Approx.
0.5 mm
Amplifier Unit
Fiber Unit
Nylon wireholder
20 mm min.
Tape
20 mm min.
Metal holder
Fiber Unit
E3X-NH

Related parts for E3X-NH21