HD64F3694FY Renesas Electronics America, HD64F3694FY Datasheet - Page 195

IC H8 MCU FLASH 32K 48-LQFP

HD64F3694FY

Manufacturer Part Number
HD64F3694FY
Description
IC H8 MCU FLASH 32K 48-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3694FY

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3694FYJV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3694FYV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
(IMIEA, IMIEB, IMIEC, or IMIED) in TSRW is set to 1 at this time, an interrupt request is
generated. The edge of the input-capture signal is selected in TIOR.
GRC and GRD can be used as buffer registers of GRA and GRB, respectively, by setting BUFEA
and BUFEB in TMRW.
For example, when GRA is set as an output-compare register and GRC is set as the buffer register
for GRA, the value in the buffer register GRC is sent to GRA whenever compare match A is
generated.
When GRA is set as an input-capture register and GRC is set as the buffer register for GRA, the
value in TCNT is transferred to GRA and the value in the buffer register GRC is transferred to
GRA whenever an input capture is generated.
GRA to GRD must be written or read in 16-bit units; 8-bit access is not allowed. GRA to GRD are
initialized to H'FFFF by a reset.
12.4
The timer W has the following operating modes.
12.4.1
TCNT performs free-running or periodic counting operations. After a reset, TCNT is set as a free-
running counter. When the CTS bit in TMRW is set to 1, TCNT starts incrementing the count.
When the count overflows from H'FFFF to H'0000, the OVF flag in TSRW is set to 1. If the OVIE
in TIERW is set to 1, an interrupt request is generated. Figure 12.2 shows free-running counting.
Normal Operation
PWM Operation
Operation
Normal Operation
Rev.5.00 Nov. 02, 2005 Page 165 of 418
Section 12 Timer W
REJ09B0028-0500

Related parts for HD64F3694FY