SAK-XC2765X-104F80L AA Infineon Technologies, SAK-XC2765X-104F80L AA Datasheet - Page 103

no-image

SAK-XC2765X-104F80L AA

Manufacturer Part Number
SAK-XC2765X-104F80L AA
Description
IC MCU 32BIT FLASH 100-LQFP
Manufacturer
Infineon Technologies
Series
XC27x5Xr
Datasheet

Specifications of SAK-XC2765X-104F80L AA

Core Processor
C166SV2
Core Size
16/32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, I²C, LIN, SPI, SSC, UART/USART, USI
Peripherals
I²S, POR, PWM, WDT
Number Of I /o
75
Program Memory Size
832KB (832K x 8)
Program Memory Type
FLASH
Ram Size
50K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
100-LFQFP
Data Bus Width
16 bit, 32 bit
Data Ram Size
32 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
76
Number Of Timers
5
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 16 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
SP000443762
4.6.5
The following parameters specify the behavior of the XC2765X bus interface.
Note: These parameters are not subject to production test but verified by design and/or
Table 29
Parameter
CLKOUT cycle time
CLKOUT high time
CLKOUT low time
CLKOUT rise time
CLKOUT fall time
1) The CLKOUT cycle time is influenced by the PLL jitter (given values apply to
Figure 21
Note: The term CLKOUT refers to the reference clock output signal which is generated
Data Sheet
For longer periods the relative deviation decreases (see PLL deviation formula).
CLKOUT
characterization.
by selecting
P2.8 and by enabling the high-speed clock driver on this pin.
External Bus Timing
CLKOUT Reference Signal
CLKOUT Signal Timing
f
SYS
as the source signal for the clock output signal EXTCLK on pin
t
5
Symbol
t
t
t
t
t
5
6
7
8
9
CC
CC 3
CC 3
CC –
CC –
t
6
Min.
XC2000 Family Derivatives / Base Line
103
t
7
40/25/12.5
Limits
Max.
3
3
1)
t
8
f
SYS
Electrical Parameters
MC_X_EBCCLKOUT
Unit Note / Test
ns
ns
ns
ns
ns
= 25/40/80 MHz).
t
Condition
9
V2.0, 2009-03
XC2765X

Related parts for SAK-XC2765X-104F80L AA