P2CF-08-E Omron, P2CF-08-E Datasheet - Page 49

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Safety Precautions (H5CX-A/-L)
If the output relay is used beyond its life expectancy, its contacts
may occasionally become fused or there may occasionally be a risk
of fire. The life expectancy of the output relay varies considerably
according to its usage. Use the output relay within its rated load and
electrical life expectancy.
Depending on the wiring, unwanted current from the AC power
supply may occasionally burn out (damage) the internal parts.
The H5CX-A/-L (except for H5CX-A11/-A11S) do not have
transformers. Therefore, there is no insulation between the power
supply and input terminals, so make sure that wiring is correct before
use.
For the power supply of an input device of the H5CX (except for
H5CX-A11/-A11S), use an isolating transformer with the primary and
secondary windings mutually isolated and the secondary winding not
grounded.
Correct Wiring Example
Incorrect Wiring Example 1
Do not ground the secondary winding. If the secondary wiring is
grounded, as shown in the following diagram, unwanted current may
occasionally burn out or damage the internal parts.
Incorrect Wiring Example 2
Do not simultaneously input signals from a single input contact or a
transistor to two or more timers that have independent power
supplies. Otherwise, the internal parts may occasionally be burnt out
or damaged by unwanted current, as shown in the following diagram.
Circuit
Circuit
Input
terminals
H5CX
Input
terminals
Input
terminals
Input
terminals
H5CX
H5CX
Isolation transformer is required.
Power supply
CAUTION
Power supply
Power supply
■ Precautions for Safe Use
Usage Precautions
Do not touch the input terminals while power is supplied. The H5CX
(except for H5CX-A11/-A11S) has a transformerless power supply
and so touching the input terminals with power supplied may result in
electric shock.
Changing the Set Values
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the use
of a constant read-in system:
Elapsed time (UP) mode: Present value ≥ set value
Remaining time (DOWN) mode: Elapsed time ≥ set value
Note: When in the remaining time mode, the amount the set value is
■ Precautions for Correct Use
Operation with a Set Value of 0
Operation with a set value of 0 will vary with the output mode. Refer
to the Timing Charts.
changed is added to or subtracted from the present value.
(The present value is set to 0.)
H5CX-B
49

Related parts for P2CF-08-E