P2CF-08-E Omron, P2CF-08-E Datasheet - Page 22

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Timing Charts
Timer Operation
The gate input is not included in the H5CX-L8@ models.
Timing
diagram
Timing
diagram
Timing
diagram
Timing
diagram
t
Control output
Control output
One-shot output
Control output
Control output
Start signal
Start signal
Start signal
Start signal
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Set value
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
Power
Power
Power
Reset
Reset
Power
Reset
Gate
Reset
Sustained output
Gate
Gate
Gate
0
0
0
0
0
0
0
0
t
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.)
t
t
t
Output mode A-1: Signal ON delay 2 (Timer resets when power comes ON.)
Output mode A-2: Power ON delay 1 (Timer resets when power comes ON.)
Output mode A: Signal ON delay 1 (Timer resets when power comes ON.)
Either one-shot output or sustained output can be selected.
t
t
t
*
**
*
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e., same
function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
*
*
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e.,
same function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing starts when the start signal goes ON, and is
reset when the start signal goes OFF.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Start signal
input
Output is instantaneous when setting is 0.
Output is instantaneous when setting is 0.
Output is instantaneous when setting is 0.
Basic Operation
Output
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Start signal
input
Output is instantaneous when setting is 0.
Start signal input is disabled during timing.
Power
Output
Basic Operation
Power
Basic Operation
Basic Operation
Output
Power
Output
Power
**
Timing
Timing
Timing
Timing
Sustained
H5CX-A/-L
22

Related parts for P2CF-08-E