MAX5965BUAX+ Maxim Integrated Products, MAX5965BUAX+ Datasheet - Page 33

IC PSE CTRLR FOR POE 36SSOP

MAX5965BUAX+

Manufacturer Part Number
MAX5965BUAX+
Description
IC PSE CTRLR FOR POE 36SSOP
Manufacturer
Maxim Integrated Products
Type
Power Over Ethernet Controller (PoE)r
Datasheet

Specifications of MAX5965BUAX+

Applications
IP Phones, Power over LAN, Network Routers and Switches
Internal Switch(s)
No
Voltage - Supply
2.4 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-BSOP (0.300", 7.5mm Width)
Supply Voltage (max)
60 V
Supply Voltage (min)
32 V
Power Dissipation
1388.9 mW
Operating Temperature Range
0 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX5965A/MAX5965B use 2 bits for each port to
set the mode of operation. Set the modes according to
Table 16a and 16b.
Setting DCD_EN_ to 1 enables the DC load disconnect
detection feature (Table 17). Setting ACD_EN_ to 1
enables the AC load disconnect feature. If enabled, the
load disconnect detection starts during power mode
Table 16a. Operating Mode Register
Table 16b. Operating Mode Status
Table 17. Load Disconnect Detection Enable Register
P4_M1
P4_M0
P3_M1
P3_M0
P2_M1
P2_M0
P1_M1
P1_M0
ACD_EN4
ACD_EN3
ACD_EN2
ACD_EN1
DCD_EN4
DCD_EN3
DCD_EN2
DCD_EN1
High-Power, Quad, Monolithic, PSE Controllers
MODE
SYMBOL
SYMBOL
00
01
10
11
ADDRESS = 12h
ADDRESS = 13h
______________________________________________________________________________________
Shutdown
Manual
Semi-auto
Auto
BIT
BIT
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
DESCRIPTION
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
MODE[1] for port 4
MODE[0] for port 4
MODE[1] for port 3
MODE[0] for port 3
MODE[1] for port 2
MODE[0] for port 2
MODE[1] for port 1
MODE[0] for port 1
Enable AC disconnect detection on port 4
Enable AC disconnect detection on port 3
Enable AC disconnect detection on port 2
Enable AC disconnect detection on port 1
Enable DC disconnect detection on port 4
Enable DC disconnect detection on port 3
Enable DC disconnect detection on port 2
Enable DC disconnect detection on port 1
for Power over Ethernet
A reset sets R12h = AAAAAAAAb where A represents
the latched-in state of the AUTO input prior to the reset.
Use software to change the mode of operation.
Software resets of ports (RESET_P_ bit, Table 23) do
not affect the mode register.
and after startup when the corresponding PGOOD_ bit
in register R10h (Table 14) goes high. A reset sets
R13h = 0000AAAAb where A represents the latched-in
state of the AUTO input prior to the reset.
DESCRIPTION
DESCRIPTION
33

Related parts for MAX5965BUAX+