MAX3301EETJ Maxim Integrated, MAX3301EETJ Datasheet - Page 28

no-image

MAX3301EETJ

Manufacturer Part Number
MAX3301EETJ
Description
USB Interface IC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX3301EETJ

Operating Supply Voltage
3 V to 4.5 V
Operating Supply Current
5 uA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX3301EETJ+
Manufacturer:
Maxim
Quantity:
37
ESD performance depends on a variety of conditions.
Contact Maxim for a reliability report that documents
test setup, methodology, and results.
Figure 22 shows the Human Body Model and Figure 23
shows the current waveform it generates when dis-
charged into a low impedance. This model consists of a
100pF capacitor charged to the ESD voltage of interest,
which is then discharged into the test device through a
1.5kΩ resistor.
The IEC 61000-4-2 standard covers ESD testing and
performance of finished equipment; it does not specifi-
cally refer to integrated circuits. The MAX3301E/
MAX3302E helps the user design equipment that meets
level 3 of IEC 61000-4-2, without the need for additional
ESD-protection components. The major difference
between tests done using the Human Body Model and
IEC 61000-4-2 is a higher peak current in IEC 61000-4-2,
due to the fact that series resistance is lower in the IEC
61000-4-2 model. Hence, the ESD-withstand voltage
measured to IEC 61000-4-2 is generally lower than that
measured using the Human Body Model. Figure 24
shows the IEC 61000-4-2 model. The Air-Gap Discharge
USB On-the-Go Transceivers and Charge Pumps
Table 17. ID Registers
28
Table 16. MAX3302E Special-Function Register 2 (Write to Address 10h or 16h to Set,
Write to Address 11h or 17h to Clear)
BIT NUMBER
REGISTER
Revision ID
______________________________________________________________________________________
Product ID
Vendor ID
4–7
0
1
2
3
xcvr_input_disc
SYMBOL
irq_mode
reg_sel
sdwn
ADDRESS
00h
01h
02h
03h
14h
15h
Set to 0 to enable shutdown mode. Set to 1 for normal operation. Only the I
interface remains active in shutdown.
Set to 0 to set INT and OE/INT as open-drain outputs. Set to 1 to set INT and
OE/INT as push-pull outputs.
S et to 0 to l eave the D+ /D - si ng l e-end ed r ecei ver inp uts connected . S et to 1 to
d i sconnect the D + /D- r ecei ver inp uts to r educe p ow er consump ti on i n audi o mod e.
Set to 0 to power TRM from V
Reserved. Set to 0 for normal operation.
Human Body Model
IEC 61000-4-2
CONTENTS
6Ah
0Bh
01h
33h
77h
41h
CC
. Set to 1 to power TRM from V
test involves approaching the device with a charged
probe. The contact discharge method connects the
probe to the device before the probe is energized.
Figure 25 shows the IEC 61000-4-2 current waveform.
The MAX3301E/MAX3302E high operating frequency
makes proper layout important to ensure stability and
maintain the output voltage under all loads. For best
performance, minimize the distance between the
bypass capacitors and the MAX3301E/MAX3302E. Use
symmetric trace geometry from D+ and D- to the USB
connector.
For the latest application details on UCSP construction,
dimensions, tape carrier information, PC board tech-
niques, bump-pad layout, and the recommended reflow
temperature profile, as well as the latest information on
reliability testing results, refer to the Application Note:
Understanding the Basics of the Wafer-Level Chip-Scale
Package (WL-CSP) available on Maxim’s website at
www.maxim-ic.com/ucsp.
CONTENTS
UCSP Applications Information
BUS
.
Layout Considerations
2
C
POWER-UP
VALUE AT
0000
1
0
0
0

Related parts for MAX3301EETJ