PEB3086 Infineon Technologies, PEB3086 Datasheet - Page 199

no-image

PEB3086

Manufacturer Part Number
PEB3086
Description
ISDN Subscriber Access Controller
Manufacturer
Infineon Technologies
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3086F
Manufacturer:
INFINEON
Quantity:
85
Part Number:
PEB3086F
Manufacturer:
HARRIS
Quantity:
104
Company:
Part Number:
PEB3086F SLLHP
Quantity:
600
Part Number:
PEB3086F1.4
Quantity:
160
Part Number:
PEB3086FV1.4
Manufacturer:
INFINEON
Quantity:
183
Part Number:
PEB3086FV1.4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEB3086FV1.4
Quantity:
1 600
Part Number:
PEB3086FV14
Manufacturer:
RENESAS
Quantity:
2 720
Part Number:
PEB3086H
Manufacturer:
INFINEON
Quantity:
9
Part Number:
PEB3086H-V1-4
Manufacturer:
INF
Quantity:
1 000
Part Number:
PEB3086H-V1-4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3086HV1.4
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3086HV1.4
0
DCI_CR
DPS_D ... Data Port Selection for D-Channel Timeslot access
0: The B-channel controller data is output on DD.
1: The B-channel controller data is output on DU.
EN_D ... Enable D-Channel Timeslot (2-bit) for B-Channel controller access
EN_BC2 ... Enable B2-Channel Timeslot (8-bit) for B-Channel controller access
EN_BC1 ... Enable B1-Channel Timeslot (8-bit) for B-Channel controller access
These bits individually enable/disable the B-channel access to the 2-bit and the two 8-bit
timeslots.
0: B-channel B/A does not access timeslot data B1, B2 or D, respectively.
1: B-channel B/A does access timeslot data B1, B2 or D, respectively.
Note: The terms B1/B2 should not imply that the 8-bit timeslots must be located in the
CS2-0 ... Channel Select for D-Channel Timeslot access
This register is used to select one of eight IOM channels. If enabled (EN_D=1), the
B-channel controller is connected to the 2-bit D-channel timeslot of that IOM channel.
Note: The reset value is determined by the channel select pins CH2-0 which are directly
4.4.6
Value after reset: A0
Read and write access to this register is only possible if IOM_CR.CI_CS = 0.
DPS_CI1 ... Data Port Selection CI1 Handler Data
0: The CI1 handler data is output on DD and input from DU
1: The CI1 handler data is output on DU and input from DD
Data Sheet
The B-channel controller data is input from DU.
The B-channel controller data is input from DD.
first/second IOM-2 timeslots, it’s simply a placeholder for the 8-bit timeslot position
selected in the registers BCH_TSDP_BC1/2.
mapped to CS2-0.
7
DCI_CR - Control Register for D and CI1 Handler
(IOM_CR.CI_CS=0)
DPS_
CI1
EN_
CI1
H
EN_D
D_
EN_B2
D_
199
EN_B1
D_
Detailed Register Description
CS2-0
0
RD/WR (53)
PEB 3086
2003-01-30
ISAC-SX