w3e16m72s-xbx White Electronic Designs Corporation, w3e16m72s-xbx Datasheet - Page 8

no-image

w3e16m72s-xbx

Manufacturer Part Number
w3e16m72s-xbx
Description
16mx72 Sdram
Manufacturer
White Electronic Designs Corporation
Datasheet
NOTES:
1. CKE is HIGH for all commands shown except SELF REFRESH.
2. A0-12 defi ne the op-code to be written to the selected Mode Register. BA0, BA1
3. A0-12 provide row address, and BA0, BA1 provide bank address.
4. A0-8 provide column address; A10 HIGH enables the auto precharge feature (non
5. A10 LOW: BA0, BA1 determine the bank being precharged. A10 HIGH: All banks
on inputs A0-12 selects the row. This row remains active
(or open) for accesses until a PRECHARGE command is
issued to that bank. A PRECHARGE command must be
issued before opening a different row in the same bank.
READ
The READ command is used to initiate a burst read access
to an active row. The value on the BA0, BA1 inputs selects
the bank, and the address provided on inputs A0-8 selects
the starting column location. The value on input A10
determines whether or not AUTO PRECHARGE is used. If
AUTO PRECHARGE is selected, the row being accessed
will be precharged at the end of the READ burst; if AUTO
PRECHARGE is not selected, the row will remain open for
subsequent accesses.
WRITE
The WRITE command is used to initiate a burst write
access to an active row. The value on the BA0, BA1 inputs
selects the bank, and the address provided on inputs A0-8
February 2005
Rev. 7
NAME (FUNCTION)
DESELECT (NOP) (9)
NO OPERATION (NOP) (9)
ACTIVE (Select bank and activate row) ( 3)
READ (Select bank and column, and start READ burst) (4)
WRITE (Select bank and column, and start WRITE burst) (4)
BURST TERMINATE (8)
PRECHARGE (Deactivate row in bank or banks) ( 5)
AUTO REFRESH or SELF REFRESH (Enter self refresh mode) (6, 7)
LOAD MODE REGISTER (2)
select either the mode register (0, 0) or the extended mode register (1, 0).
persistent), while A10 LOW disables the auto precharge feature; BA0, BA1 provide
bank address.
precharged and BA0, BA1 are “Don’t Care.”
White Electronic Designs
NAME (FUNCTION)
WRITE ENABLE (10)
WRITE INHIBIT (10)
TRUTH TABLE – COMMANDS (NOTE 1)
TRUTH TABLE – DM OPERATION
8
6. This command is AUTO REFRESH if CKE is HIGH; SELF REFRESH if CKE is LOW.
7. Internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care”
8. Applies only to read bursts with auto precharge disabled; this command is undefi ned
9. DESELECT and NOP are functionally interchangeable.
10. Used to mask write data; provided coincident with the corresponding data.
selects the starting column location. The value on input A10
determines whether or not AUTO PRECHARGE is used. If
AUTO PRECHARGE is selected, the row being accessed
will be precharged at the end of the WRITE burst; if AUTO
PRECHARGE is not selected, the row will remain open for
subsequent accesses. Input data appearing on the D/Qs is
written to the memory array subject to the DQM input logic
level appearing coincident with the data. If a given DQM
signal is registered LOW, the corresponding data will be
written to memory; if the DQM signal is registered HIGH,
the corresponding data inputs will be ignored, and a WRITE
will not be executed to that byte/column location.
PRECHARGE
The PRECHARGE command is used to deactivate the
open row in a particular bank or the open row in all banks.
The bank(s) will be available for a subsequent row access
a specifi ed time (t
issued. Except in the case of concurrent auto precharge,
where a READ or WRITE command to a different bank is
CS#
H
DM
L
L
L
L
L
L
L
L
H
L
except for CKE.
(and should not be used) for READ bursts with auto precharge enabled and for
WRITE bursts.
White Electronic Designs Corporation • (602) 437-1520 • www.wedc.com
RAS#
H
H
H
DQs
Valid
X
L
H
L
L
L
X
RP
) after the PRECHARGE command is
CAS#
X
H
H
H
H
W3E16M72S-XBX
L
L
L
L
WE#
X
H
H
H
H
L
L
L
L
Bank/Row
Bank/Col
Bank/Col
Op-Code
ADDR
Code
X
X
X
X

Related parts for w3e16m72s-xbx