AD5361 Analog Devices, AD5361 Datasheet - Page 24

no-image

AD5361

Manufacturer Part Number
AD5361
Description
16-Channel, 14-Bit, Serial Input, Voltage-Output DAC
Manufacturer
Analog Devices
Datasheet

Specifications of AD5361

Resolution (bits)
14bit
Dac Update Rate
540kSPS
Dac Settling Time
20µs
Max Pos Supply (v)
+16.5V
Single-supply
No
Dac Type
Voltage Out
Dac Input Format
Ser,SPI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5361BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD5361BCPZ
Quantity:
220
Part Number:
AD5361BSTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD5361BSTZ-REEL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
AD5360/AD5361
SPECIAL FUNCTION MODE
If the mode bits are 00, then the special function mode is
selected, as shown in Table 14. Bits I21 to I16 of the serial data
word select the special function, while the remaining bits are
Table 14. Special Function Mode
I23
0
Table 15. Special Function Codes
Special Function Code
S5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
S4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I22
0
S3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
I21
S5
S2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
I20
S4
S1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
I19
S3
S0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
I18
S2
Data (F15 to F0)
0000 0000 0000 0000
XXXX XXXX XXXX X [F2:F0]
XX [F13:F0]
XX [F13:F0]
Reserved
See Table 16
XXXX XXXX [F7:F0]
XXXX XXXX [F7:F0]
Reserved
Reserved
Reserved
XXXX XXXX [F7:F0]
XXXX XXXX XX [F5:F0]
XXXX XXXX XXXX XX [F1:F0]
I17
S1
I16
S0
I15
F15
I14
F14
Rev. A | Page 24 of 28
I13
F13
Action
NOP.
Write control register.
F4 = 1: temperature over 130°C.
F4 = 0: temperature under 130°C.
Read-only bit. This bit should be 0 when writing to the control register.
F3 = 1: PEC error.
F3 = 0: No PEC error. Reserved.
Read-only bit. This bit should be 0 when writing to the control register.
F2 = 1: select Register X1B for input.
F2 = 0: select Register X1A for input.
F1 = 1: enable temperature shutdown.
F1 = 0: disable temperature shutdown.
F0 = 1: soft power-down.
F0 = 0: soft power-up.
Write data in F13 to F0 to OFS0 register.
Write data in F13 to F0 to OFS1 register.
Select register for readback.
Write data in F7 to F0 to A/B Select Register 0.
Write data in F7 to F0 to A/B Select Register 1.
Block write A/B select registers.
F7 to F0 = 0: write all 0s (all channels use X2A register).
F7 to F0 = 1: write all 1s (all channels use X2B register).
F5 = 1: monitor enable.
F5 = 0: monitor disable.
F4 = 1: monitor input pin selected by F0.
F4 = 0: monitor DAC channel selected by F3:F0
(0000 = DAC0; 1111 = DAC15).
F3 = not used if F4 = 1.
F2 = not used if F4 = 1.
F1 = not used.
F0 = 0: MON_IN0 selected for monitoring (if F4 and F5 = 1).
F0 = 1: MON_IN1 selected for monitoring (if F4 and F5 = 1).
GPIO configure and write.
F1 = 1: GPIO is an output. Data to output is written to F0.
F1 = 0: GPIO is an input. Data can be read from F0 on readback.
I12
F12
data required for execution of the special function, for example
the channel address for data readback.
The codes for the special functions in Table 16 show the
addresses for data readback.
I11
F11
I10
F10
I9
F9
I8
F8
I7
F7
I6
F6
I5
F5
I4
F4
I3
F3
I2
F2
I1
F1
I0
F0

Related parts for AD5361