AD7799 Analog Devices, AD7799 Datasheet - Page 20

no-image

AD7799

Manufacturer Part Number
AD7799
Description
3-Channel, Low Noise, Low Power, 24-Bit, Sigma Delta ADC with On-Chip In-Amp
Manufacturer
Analog Devices
Datasheet

Specifications of AD7799

Resolution (bits)
24bit
# Chan
3
Sample Rate
n/a
Interface
Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
(2Vref/PGA Gain) p-p
Adc Architecture
Sigma-Delta
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7799BRU
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZ
Manufacturer:
ADI
Quantity:
2 500
Part Number:
AD7799BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7799BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZ-REEL
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7799BRUZ-REEL
Manufacturer:
AD
Quantity:
800
Part Number:
AD7799BRUZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7799BRUZREEL
Manufacturer:
PH
Quantity:
6 469
AD7798/AD7799
Single-Conversion Mode
In single-conversion mode, the AD7798/AD7799 is placed in
power-down mode after conversions. When a single conversion
is initiated by setting MD2, MD1, and MD0 to 0, 0, and 1 in the
mode register, the AD7798/AD7799 powers up, performs a
single conversion, and then returns to power-down mode. The
on-chip oscillator requires approximately 1 ms to power up. A
conversion requires a time period of 2 × t
low to indicate the completion of a conversion. When the data-
word has been read from the data register, DOUT/ RDY goes
high. If CS is low, DOUT/ RDY remains high until another
conversion is initiated and completed. The data register can be
read several times if required, even when DOUT/ RDY is high.
DOUT/RDY
DOUT/RDY
SCLK
SCLK
DIN
DIN
CS
CS
0x08
ADC
0x200A
. DOUT/ RDY goes
0x58
Figure 17. Continuous Conversion
Figure 16. Single Conversion
Rev. A | Page 20 of 28
DATA
Continuous-Conversion Mode
This is the default power-up mode. The AD7798/AD7799
continuously converts, with the RDY bit in the status register
going low each time a conversion is complete. If CS is low, the
DOUT/ RDY line also goes low when a conversion is complete.
To read a conversion, the user can write to the communication
register, indicating that the next operation is a read of the data
register. The digital conversion is placed on the DOUT/ RDY
pin as soon as SCLK pulses are applied to the ADC. DOUT/ RDY
returns high when the conversion is read. The user can reread
this register if required. However, the user must ensure that the
data register is not accessed at the completion of the next
conversion, or the new conversion word is lost.
0x58
0x58
DATA
DATA

Related parts for AD7799