PEB20320H-V34 Infineon Technologies, PEB20320H-V34 Datasheet - Page 217

IC CONTROLR 32-CH HDLC 160-MQFP

PEB20320H-V34

Manufacturer Part Number
PEB20320H-V34
Description
IC CONTROLR 32-CH HDLC 160-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20320H-V34

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, V.110, X.30
Voltage - Supply
5V
Current - Supply
100mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
160-BSQFP
Includes
Automatic Flag Detection, CRC Generation and Checking, Error Detection, Interframe-Time-Fill Change Detection
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
Number Of Circuits
-
Other names
PEB20320H-V34
PEB20320H-V34IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20320H-V34
Manufacturer:
Infineon Technologies
Quantity:
10 000
5.3.1
As described in the previous section, the MUNICH32 in a steady state condition
consumes approximately 5% of the system bus bandwidth. Based on the conditions
previously described, a set of equations can be used to describe the MUNICH32 system
bus behavior. Other MUNICH32 systems can be evaluated using these equations. The
Bus occupancy is defined as the ratio of the time required for memory accesses for that
data to the time used to send the data. The two equations are defines as follows:
Time used for memory accesses:
transfer this
Time used to send the data is the number of transmitted bits per time slot multiplied by
the frame time:
From the previous example, the variables are assigned the following values:
Variable n
Value
User’s Manual
= Number of received bits plus transmitted bits multiplied by the time required to
= {([6 + (1 + m)]
= ((4 + n)
information to/from memory.
6 for receive descriptor access
5 for transmit descriptor access
(1 + m) for data access where m is the largest integer smaller (n – 1)/4
(n is the number of transmitted data bytes).
rc is the number of receive channels.
tc is the number of transmit channels.
(1 + 1/ba) is the bus arbitration time
sclk is the system clock (61 ns for 16.384 MHz)
NC is the number of memory clocks per bus operation (0ws = 4, 1WS = 5, etc.).
Bus Occupancy Calculations
32 bytes 7
4 because shared flags are not used + 2 byte CRC
n is the number of octets to transmit
abtc = assigned bits to channel
e.g. a channel with one time slot of 1 bit would require 8/1 = 8 time slots to
transmit a single octet.
8/abtc)
m
rc) + (5 + (1 + m)]
125 s
rc
32
tc
32
217
tc)}
(1 + 1/ba) sclk
1.1
(1 + 1/ba)
61 ns
NC
Application Notes
sclk
NC
4
PEB 20320
abtc
8
01.2000

Related parts for PEB20320H-V34