PEB20320H-V34 Infineon Technologies, PEB20320H-V34 Datasheet - Page 18

IC CONTROLR 32-CH HDLC 160-MQFP

PEB20320H-V34

Manufacturer Part Number
PEB20320H-V34
Description
IC CONTROLR 32-CH HDLC 160-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20320H-V34

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, V.110, X.30
Voltage - Supply
5V
Current - Supply
100mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
160-BSQFP
Includes
Automatic Flag Detection, CRC Generation and Checking, Error Detection, Interframe-Time-Fill Change Detection
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-
Number Of Circuits
-
Other names
PEB20320H-V34
PEB20320H-V34IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20320H-V34
Manufacturer:
Infineon Technologies
Quantity:
10 000
User’s Manual
Pin Definitions and Functions (cont’d)
Pin No.
P-MQFP-160-1
80
66
Symbol
HLDAO
BGO
AR
Output (O)
Input (I)
O
O
I
18
Function
Bus Hold Acknowledge Passing ON
(Intel bus mode)
If another MUNICH32 has initiated a
HOLD REQUEST the HOLD
ACKNOWLEDGE is passed on via
HLDAO. The MUNICH32 does not give
another HOLD REQUEST before the
HOLD ACKNOWLEDGE has been
deactivated in order to prevent blocking in
the case of continuous request by one
MUNICH32.
Bus Grant Acknowledge (Motorola bus
mode)
If the MUNICH32 has not requested the
bus mastership it passes on the BUS
GRANT. The MUNICH32 does not give
another BUS REQUEST before the BUS
REQUEST and the BUS GRANT
ACKNOWLEDGE have been deactivated
in order to prevent blocking in the case of
continuous request by one MUNICH32.
Action Request
AR must be pulsed low to cause an action
of the MUNICH32. The AR is activated for
updating the mode and channel
configurations, setting a test loop, or
initializing the interrupt queue. The
min. time between Reset and first AR is
500 s.
Introduction
PEB 20320
01.2000

Related parts for PEB20320H-V34