CC-9M-NA37-Z1-B Digi International, CC-9M-NA37-Z1-B Datasheet - Page 36

no-image

CC-9M-NA37-Z1-B

Manufacturer Part Number
CC-9M-NA37-Z1-B
Description
MOD 9M 64MB SDRAM 128MB FLASH 25
Manufacturer
Digi International
Series
-r
Datasheet

Specifications of CC-9M-NA37-Z1-B

Module/board Type
Core Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Networking
www.digiembedded.com
Touch screen
interface modes
Reset controller
JTAG
1. Normal conversion mode
Single Conversion Mode is used for General Purpose ADC Conversion. This mode can
be activated by:
2. Separate X/Y position conversion mode is activated as follows:
3. Auto (Sequential) X/Y Position Conversion Mode is activated as follows:
4. Waiting for Interrupt Mode is activated as follows:
5. Standby Mode
Standby Mode is activated when ADCCON [2] is set to '1.'
In this mode, A/D conversion operation is halted and ADCDAT0, ADCDAT1 register
contains the previous converted data.
On the module there is an Analog Devices ADM811SARTZ used. This device monitors
3.3V and has RSTIN# as debounced manual reset input and through a series resistor of
470R produces PWRGOOD as output. The voltage threshold is 2.93V. Reset output
length is typically 240ms.
The standard JTAG signals are provided at the system connector. A JTAG/Multi-ICE
connector has to be provided at the base board for debugging.
The signal DEBUGEN# (CONF0) from the base board to the module is necessary, to
be able to switch on and off a connection between the system reset and the JTAG
reset.
1
2
1
2
1
2
1
2
Set the ADCCON (ADC Control Register), and
Set the read and write to the ADCDAT0 (ADC Data Register 0).
X-Position Mode writes X-Position Conversion Data to ADCDAT0, so Touch
Screen Interface generates the Interrupt source to Interrupt Controller.
Y-Position Mode writes Y-Position Conversion Data to ADCDAT1, so Touch
Screen Interface generates the Interrupt source to Interrupt Controller.
Touch Screen Controller sequentially converts the X-Position or Y-Position
that is touched.
After touch controller writes X-measurement data to ADCDAT0 and writes
Y-measurement data to ADCDAT1, the Touch Screen Interface generates
Interrupt source to Interrupt Controller in Auto Position Conversion Mode.
The Touch Screen Controller generates an interrupt (INT_TC) signal when
the stylus is down. Waiting for Interrupt Mode setting value is
rADCTSC=0xd3; // XP_PU, XP_Dis, XM_Dis, YP_Dis, YM_En.
After the Touch Screen Controller generates interrupt signal (INT_TC), the
user must wait for the interrupt mode to be cleared (XY_PST sets to the No
operation Mode).
36