Operation
J FUNCTIONS
Function
Output
Functions
Input
Functions
Linear output (with light/dark
mode selection function)
HIGH/PASS output (with
discrimination output setting
and short-circuit protection
functions)
LOW/NG output (with
discrimination output setting
and short-circuit protection
functions)
LD (laser diode) OFF input
Forced-zero input
Timing input
Bank selection input
Hold reset input
Description
Outputs voltage (1 to 5 VDC) proportional to the amount of incident
light or light interruption. The light/dark mode selector switch is used
to select either light or dark mode.
Laser beams will be stopped when this input turns ON.
“ldoff” appears on the display, and linear output, HIGH/LOW
discrimination indicator and output remain in the previous state.
All displays except the LD ON indicator and all outputs retain the
previous values.
Displays the measured value as zero when the unit is set to length
(mm). The value is set if forced-zero input is ON for 0.2 to 0.8 s and
cleared if it is ON for 1 s or more.
To set forced-zero or clear forced-zero, press and hold down the
SET Key for 3 s while in RUN mode.
The Z4LB V2 has two banks in which thresholds can be set
independently.
If the bank selection input is enabled, the thresholds to be used
for judgment can be switched.
The default setting is disabled.
Resets the held value if this input turns ON during hold measurement.
One of the following discrimination output modes can be selected
according to the application.
HIGH/LOW Output Mode: Turns ON when measured value ≥ LOW
threshold PASS/NG Output Mode: Turns ON when measured value
≤ LOW threshold or measured value ≥ HIGH threshold
HIGH/LOW Inverted Output Mode: Turns ON when measured value
≤ LOW threshold
The default setting is HIGH/LOW Output Mode.
Forcibly turns OFF HIGH/PASS or LOW/NG discrimination output
if this input turns ON during normal measurement.
Controls sampling timing if this input turns ON during hold
measurement.
The default setting is normal.
One of the following discrimination output modes can be selected
according to the application.
HIGH/LOW Output Mode: Turns ON when measured value ≤ HIGH
threshold PASS/NG Output Mode: Turns ON when LOW threshold
< measured value < HIGH threshold HIGH/LOW Inverted Output
Mode: Turns ON when measured value ≥ HIGH threshold
The default setting is HIGH/LOW Output Mode.
Light mode
Amount of incident light (mm)
(This table continues on the next page.)
Bank
Bank 1
Bank 2
NPN type
Open or connected to
12 to 24 VDC
Connected to 0 V
Dark mode
Amount of light interruption (mm)
PNP type
Open or connected to 0 V
Connected to 12 to
24 VDC