AD7156BCPZ-REEL7 Analog Devices Inc, AD7156BCPZ-REEL7 Datasheet - Page 16

IC CDC 2CH 12BIT 1.8V 10LFCSP

AD7156BCPZ-REEL7

Manufacturer Part Number
AD7156BCPZ-REEL7
Description
IC CDC 2CH 12BIT 1.8V 10LFCSP
Manufacturer
Analog Devices Inc
Type
Capacitance-to-Digital Converterr
Datasheet

Specifications of AD7156BCPZ-REEL7

Resolution (bits)
12 b
Data Interface
Serial
Sampling Rate (per Second)
100k
Voltage Supply Source
Single Supply
Voltage - Supply
1.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-LFCSP
Sampling Rate
100SPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
1.8V To 3.6V
Supply Current
70µA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
AD7156BCPZ-REEL7TR
AD7156
STATUS REGISTER
Address Pointer 0x00
8 Bits, Read Only
Default Value 0x53 Before Conversion, 0x54 After Conversion
The status register indicates the status of the part. The register can be read via the 2-wire serial interface to query the status of the outputs,
check the CDC finished conversion, and check whether the CAPDAC has been changed by the auto-DAC function.
Table 6. Status Register Bit Map
Bit 7
PwrDown
(0)
1
Table 7. Status Register Bit Descriptions
Bit
7
6
5
4
3
2
1
0
The default values are given in parentheses.
Mnemonic
PwrDown
DacStep2
OUT2
DacStep1
OUT1
C1/C2
RDY2
RDY1
Bit 6
DacStep2
(1)
Description
PwrDown = 1 indicates that the part is in a power-down.
DacStep2 = 0 indicates that the Channel 2 CAPDAC value was changed after the last CDC conversion as part of
the auto-DAC function. The bit value is updated after each finished CDC conversion on this channel.
OUT2 = 1 indicates that the Channel 2 data (CIN2 capacitance) crossed the threshold, according to the selected
comparator mode of operation. The bit value is updated after each finished CDC conversion on this channel.
DacStep1 = 0 indicates that the Channel 1 CAPDAC value was changed during the last conversion as part of the
auto-DAC function. The bit value is updated after each finished CDC conversion on this channel.
OUT1 = 1 indicates that the Channel 1 data (CIN1 capacitance) crossed the threshold, according to the selected
comparator mode of operation. The bit value is updated after each finished CDC conversion on this channel.
C1/C2 = 0 indicates that the last finished CDC conversion was on Channel 1.
C1/C2 = 1 indicates that the last finished CDC conversion was on Channel 2.
RDY2 = 0 indicates a finished CDC conversion on Channel 2. The bit is reset back to 1 when the Channel 2 data
register is read via the serial interface or after a part reset or power-up.
RDY1 = 0 indicates a finished CDC conversion on Channel 1. The bit is reset back to 1 when the Channel 1 data
register is read via serial interface or after a part reset or power-up.
1
Bit 5
OUT2
(0)
Bit 4
DacStep1
(1)
Rev. 0 | Page 16 of 28
Bit 3
OUT1
(0)
Bit 2
C1/C2
(0)
Bit 1
RDY2
(1)
Bit 0
RDY1
(1)

Related parts for AD7156BCPZ-REEL7