TSA1204IFT STMicroelectronics, TSA1204IFT Datasheet - Page 24

IC CONV A/D 2-CH 12-BIT 48-TQFP

TSA1204IFT

Manufacturer Part Number
TSA1204IFT
Description
IC CONV A/D 2-CH 12-BIT 48-TQFP
Manufacturer
STMicroelectronics
Datasheet

Specifications of TSA1204IFT

Number Of Bits
12
Sampling Rate (per Second)
20M
Data Interface
Parallel
Number Of Converters
2
Power Dissipation (max)
155mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5435-2
TSA1204IFT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSA1204IFT
Manufacturer:
PHI
Quantity:
45
Part Number:
TSA1204IFT
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
TSA1204IFT
Manufacturer:
ST
0
Practical application examples
9
9.1
9.2
24/31
Practical application examples
Digital interface applications
The wide external buffer power supply range of the TSA1204 makes it a perfect choice for
plugging into 2.5 V or 3.3 V low voltage DSPs or digital interfaces.
Medical imaging application
Driven by the demand of the applications requiring nowadays either portability or ahigh
degree of parallelism (or both), this product satisfies the requirements of medical imaging
and telecom infrastructures.
The typical system diagram in
is sent into a living body via the transducer and how the energy reflected back is analyzed.
Figure 32. Medical imaging application
The transducer is a piezoelectric ceramic such as zirconium titanate. The whole array can
reach up to 512 channels. The TX beam former, amplified by the HV TX amps, delivers up to
100 V amplitude excitation pulses with phase and amplitude shifts. The mux and T/R switch
is a two-way input signal transmitter/output receiver.
To compensate for skin and tissues attenuation effects, the time gain compensation (TGC)
amplifier is an exponential amplifier that enables the amplification of low voltage signals to
the ADC input range. Differential output structure with low noise and very high linearity are
mandatory factors.
These applications need high speed, low power and high performance ADCs. 10-12 bit
resolution is necessary to lower the quantification noise. As multiple channels are used, a
dual converter is a must for room saving issues.
The input signal is in the range of 2 to 20 MHz (mainly 2 to 7 MHz) and the application uses
mostly a 4 over-sampling ratio for spurious free dynamic range (SFDR) optimization.
The next RX beam former and processing blocks enable the analysis of the output channels
versus the input beam.
Mux and
switches
Figure 32
T/R
HV TX amps
shows how a narrow input beam of acoustic energy
TGC amplifier
ADC
TX beam
former
and display
Processing
RX beam
former
TSA1204

Related parts for TSA1204IFT