S201MB40

Manufacturer Part Number
S201MB40
Description
MCB, 1 POLE, 40A, 10KA, B CURVE
Manufacturer
ABB
Series
System Pro M Compactr
Datasheet

Specifications of S201MB40

No. Of Poles
1
Voltage Rating Vac
230V
Mounting Type
DIN Rail
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
IEC/EN 60898, IEC/EN 60947-2, VDE 0641 Part 11, UL 1077, CSA
Current Rating
40A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
System
pro M compact
Use of S 200/S 200 M miniature circuit-breakers in direct current circuits 60 VDC/125 VDC
In DC systems up to 60 VDC or, as the case may be, series connection up to 125 VDC, customary S 200/S 200 M series MCBs can be used.
Polarity does not need to be taken into consideration, the outgoing circuit may be implemented from above or below the device.
For higher direct voltage up to 440 VDC devices of the S 280 UC series must be used.
Example for max. permissible voltages between conductors depending on the number of poles and type of connection.
Fusing of lighting currents
1. Filament lamps and fluorescent lamps
In the case of multipole MCBs, the value is reduced by 20 %. Tripping charcteristic type C allows for light currents up to the rated current
of the MCB,
for fusing of:
2. High-pressure discharge lamps
Starting current: ca. 1.7 x lamp current
Recovery time: ca. 3 ... 5 min.
According to the type of lamp, line impedance and start-stop torque, the so-called rectifier effect may occur which superimposes the
starting current of the lamp for some half-waves.
In the most unfavorable circumstances, inrush currents of 15 times of the lamp nominal current may ensue.
To avoid nuisance tripping, MCBs with K-type characteristic should not carry loads higher than 0.6-fold of the lamp current. The load factor
indicated refers to the least favorable case (proximity to transformer, low line impedances).
Examples for different voltages between a conductor and earth where voltages between conductors are identical:
The following table indicates the maximum number of fluorescent lamps that can be protected with a single-pole miniature circuit-breaker.
electronic ballast: twin-lamp style, jointly switched number of lamps
Characteristic/
rated current
10
16
20
25
filament lamps
fluorescent lamps
®
18/20 W
27
43
53
66
Miniature circuit-breakers
S 200/S 200 M series
conventional ballast
non-compensated
36/40 W
23
37
46
58
a) non-compensated
b) shunt compensated (cos
c) electronic load
58/65 W
15
24
30
37
18/20 W
32
51
64
82
conventional ballast
shunt compensated
= 0.95)
36/40 W
32
51
64
82
58/65 W
20
33
41
53
18/20 W
18
26
33
42
electronic ballast
36/40 W
18
26
33
42
58/65 W
12
15
19
8
15