A165E-M-02 Omron, A165E-M-02 Datasheet - Page 41

SWITCH, EMERGENCY STOP, DPST-NC, 250VAC

A165E-M-02

Manufacturer Part Number
A165E-M-02
Description
SWITCH, EMERGENCY STOP, DPST-NC, 250VAC
Manufacturer
Omron
Series
A165Er
Datasheets

Specifications of A165E-M-02

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Switch Terminals
Solder
Actuator Length
20mm
Ip Rating
IP65
Pole Throw Configuration
DPST
Switch Function Configuration
N.C.
Current Rating (max)
5A
Operating Temp Range
-10C to 55C
Contact Form
DPST - NC
Actuator Diameter
40mm
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
A3C
Note: 1. With alternate-operation models, one operation cycle consists of set and reset operations.
Note: The value for LTA min. applies to alternate-operation mod-
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Life expectancy
Weight
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
OF max.
RF min.
TT
LTA min.
(See note.)
PT max.
SPDT
Contact name
Characteristics
Operating Characteristics
Contact Form
2. The figure given above for the dielectric strength between lamp terminals is for when there is no LED lamp or incandescent lamp
3. The weight indicated here applies to the lighted models (SPST-NO+SPST-NC).
els only.
mounted.
2.45 N
0.29 N
Approx. 3.5 mm
0.5 mm
2.5 mm
NO
NC
Contact form
Mechanical:
Electrical: 20 operations/minute max.
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity and between lamp
terminals (See note 2.)
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity and also between
each terminal and ground
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (No malfunctions for more than 1 s.)
Destruction: 500 m/s
Malfunction: 150 m/s
Mechanical:
Electrical: 100,000 operations min.
Approx. 5 g (See note 3.)
–10°C to 55°C (with no icing or condensation)
35% to 85%
–25°C to 65°C
IP40
Class II
175
3 (IEC947-5-1)
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max. (See note 1.)
Momentary-action models: 1,000,000 operations min.
Alternate-action models: 100,000 operations min. (See note 1.)
NO
NC
2
2
(No malfunctions for more than 1 s.)
UL (File No. E41515)
CSA (File No. LR45258-31)
Rating
Standard
1 A at 125 VAC
0.5 A at 250 VAC
1 A at 30 VDC
Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Approved by Standards
A3C
39