A165E-M-02 Omron, A165E-M-02 Datasheet - Page 186

SWITCH, EMERGENCY STOP, DPST-NC, 250VAC

A165E-M-02

Manufacturer Part Number
A165E-M-02
Description
SWITCH, EMERGENCY STOP, DPST-NC, 250VAC
Manufacturer
Omron
Series
A165Er
Datasheets

Specifications of A165E-M-02

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Switch Terminals
Solder
Actuator Length
20mm
Ip Rating
IP65
Pole Throw Configuration
DPST
Switch Function Configuration
N.C.
Current Rating (max)
5A
Operating Temp Range
-10C to 55C
Contact Form
DPST - NC
Actuator Diameter
40mm
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Install in 22-dia. or 25-dia. Panel Cutout
• Direct opening mechanism to open the circuit when the contact
• Safety lock mechanism prevents operating errors.
• Easy mounting and removal of Switch Blocks using a lever.
• Mount three Switch Units in series to improve wiring efficiency.
• Finger protection mechanism on Switch Unit provided as a stan-
• Install using either round, or forked crimp terminals.
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)
Note: Refer to the Common Precautions for Pushbutton Switches on
Model Number Structure
Completely Assembled
Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch.
184
2. Head Size
Code
welds
dard feature.
Note: Lighted Emergency Stop
MP
LP
S
M
L
SK
MK
1. Lighted/Non-lighted
Emergency Stop Switch
A22E
Code
None Non-lighted
L
Model Number Legend
page 14, as well as the “Safety Precautions” on page 201.
Switches are available only
for the medium (M). push-
lock turn-reset models.
Medium
40 dia.
Large
60 dia.
Small
30 dia.
Medium
40 dia.
Large
60 dia.
Small
30 dia.
Medium
40 dia.
Lighted (See note.)
Size
.
Description
Push-pull
Push-lock turn-reset
Push-lock key reset
Description
3. Light Source
Note: 1 The LED lamp (24 VAC/VDC) can be
Code
Without Voltage Reduction Unit
A22E@-@-@-@-@
6D
6A
12A
24A
T1
T2
None Non-lighted
With Voltage Reduction Unit
None Non-lighted
2. Equipped with 24-VAC/DC LED.
lit by directly applying 110 VAC/VDC
(220 VAC/VDC) to the lamp terminal.
LED incorporates the 24-VAC/VDC
models.
LED
LED
Operating Voltage
1
6 VDC
6 VAC
12 VAC/VDC
24 VAC/VDC
100 VAC
200 VAC
2
3
4
5
4. Contacts
Code
01
11
02
SPST-NC
SPST-NO + SPST-NC
DPST-NC
Description
5. Configuration
Code
None
B
Switch only
Switch with Integrated
Control Box
Configuration