P6021 Tektronix, P6021 Datasheet - Page 20

no-image

P6021

Manufacturer Part Number
P6021
Description
Test Probes 60MHZ, 250A 5 FT, w/term
Manufacturer
Tektronix
Datasheet

Specifications of P6021

Color
Black
Equipment Type
Test Probe Set
Accessory Type
AC Current Probe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
AC current measurements
Service Information
Figure 3: Probe and termination input current vs. frequency derating
8
100 A
AMPS
20 A
10 A
P-P
0.1A
1 A
10 Hz
100 Hz
Table 3: Maximum ratings
Characteristic
Maximum continuous (CW) current
Maximum Pulse Current
Maximum voltage on bare wire*
*
10mA/mV
2 mA/mV
10 mA/mV
An insulated conductor is any conductor that is surrounded by an insulating
material that is capable of isolating the voltage present on the conductor. Lacquer
coatings like those typically found on transformer windings do not provide
sufficient, reliable insulation for use with current probes. The lacquer coating can be
easily nicked or damaged, which compromises the insulating capabilities of the
lacquer coating.
2 mA/mV
1 kHz
FREQUENCY
1 MHz
Information
Refer to Figure 3 for frequency derating curves
5 A
15 A
250 A peak, not to exceed 500 (A · s) or 5 A
(A · s) product greater than 500 (A · s) reduces
probe output to zero due to core saturation
30 Vrms, 42 Vpk, 60 VDC, for voltages above these
limits, use insulated conductors only.
p-p
p-p
sine wave between 1.2 kHz and 5 MHz
sine wave between 300 Hz and 5 MHz
10 MHz
P6021 Instruction Manual
100 MHz
RMS
. An