SI4313-B1-FM Silicon Laboratories Inc, SI4313-B1-FM Datasheet - Page 19

IC RX FSK 315-915MHZ 20VQFN

SI4313-B1-FM

Manufacturer Part Number
SI4313-B1-FM
Description
IC RX FSK 315-915MHZ 20VQFN
Manufacturer
Silicon Laboratories Inc
Series
EZRadio®r
Type
ISM Receiverr
Datasheets

Specifications of SI4313-B1-FM

Package / Case
20-VQFN
Mfg Application Notes
Si4313 Register Desc AppNote
Frequency
315MHz, 434MHz, 868MHz, 915MHz
Sensitivity
-118dBm
Data Rate - Maximum
128kbps
Modulation Or Protocol
FSK, GFSK, OOK
Applications
Data Logging, Health Monitors, Remote Control, Weather Station
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Operating Frequency
315 MHz to 915 MHz
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Current
100 nA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Current - Receiving
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1980-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI4313-B1-FM
Quantity:
2
Part Number:
SI4313-B1-FMR
Manufacturer:
TI
Quantity:
10 000
Part Number:
SI4313-B1-FMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
3.2. Operating Mode Control
There are three primary states in the Si4313 radio state machine: SHUTDOWN, IDLE, and RECEIVE. The
SHUTDOWN state is designed to completely shut down the radio to minimize current consumption. There are five
different configurations/options for the IDLE state that can be selected to optimize the Si4313 for the application
requirements.
"Register 07h. Operating Mode and Function Control 1" controls which operating mode/state is selected. The RX
state may be reached automatically from any of the IDLE states by setting the rxon bit in "Register 07h. Operating
Mode and Function Control 1". Table 10 shows each of the operating modes with the time required to reach RX
mode as well as the current consumption of each mode.
The Si4313 includes a low-power digital regulated supply (LPLDO), which is internally connected in parallel to the
output of the main digital regulator (and is available externally at the VR_DIG pin); this common digital supply
voltage is connected to all digital circuit blocks, including the digital modem, crystal oscillator, SPI, and register
space. The LPLDO has extremely low quiescent current consumption but limited current supply capability; it is
used only in the IDLE-STANDBY and IDLE-SLEEP modes.
Shut Down State
Idle States
RX State
Standby Mode
Sleep Mode
Sensor Mode
Ready Mode
Tune Mode
State Mode
SHUTDOWN
Table 10. Operating Modes Response Time
Figure 6. State Machine Diagram
Response Time to RX
*Five different options for IDLE
16.8 ms
800 µs
800 µs
800 µs
200 µs
200 µs
N/A
Rev. 1.0
IDLE*
Current in State/Mode (µA)
18.5 mA
800 µA
450 nA
8.5 mA
RX
15 nA
1 µA
1 µA
Si4313-B1
19