ATTINY167-15XZ Atmel, ATTINY167-15XZ Datasheet - Page 235

MCU AVR 16K FLASH 15MHZ 20-TSSOP

ATTINY167-15XZ

Manufacturer Part Number
ATTINY167-15XZ
Description
MCU AVR 16K FLASH 15MHZ 20-TSSOP
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY167-15XZ

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
I²C, LIN, SPI, UART/USART, USI
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
16
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
20-TSSOP
For Use With
ATSTK600-SOIC - STK600 SOCKET/ADAPTER FOR SOIC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
21.7.6
21.7.7
21.7.8
7728G–AVR–06/10
Reading the Flash
Reading the EEPROM
Programming the Fuse Low Bits
PAGEL / BS1
RESET +12V
Figure 21-4. Programming the EEPROM Waveforms
The algorithm for reading the Flash memory is as follows (refer to
page 232
The algorithm for reading the EEPROM memory is as follows (refer to
Flash” on page 232
The algorithm for programming the Fuse Low bits is as follows (refer to
Flash” on page 232
XA1 / BS2
RDY/BSY
1. A: Load Command “0000 0010
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The Flash word low byte can now be read at DATA.
5. Set BS1 to “1”. The Flash word high byte can now be read at DATA.
6. Set OE to “1”.
1. A: Load Command “0000 0011
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA.
5. Set OE to “1”.
1. A: Load Command “0100 0000
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
XTAL1
DATA
XA0
WR
OE
for details on Command and Address loading):
0x11
A
ADDR. HIGH
for details on Command and Address loading):
for details on Command and Data loading):
G
ADDR. LOW
B
DATA
C
b
b
b
”.
”.
”.
XX
E
ADDR. LOW
B
ATtiny87/ATtiny167
DATA
C
K
XX
E
“Programming the Flash” on
L
“Programming the
“Programming the
235