ST72F324J6T6 STMicroelectronics, ST72F324J6T6 Datasheet - Page 28

IC MCU 8BIT 32K 44-TQFP

ST72F324J6T6

Manufacturer Part Number
ST72F324J6T6
Description
IC MCU 8BIT 32K 44-TQFP
Manufacturer
STMicroelectronics
Series
ST7r
Datasheets

Specifications of ST72F324J6T6

Core Processor
ST7
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
3.8 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
44-TQFP, 44-VQFP
Controller Family/series
ST7
No. Of I/o's
32
Ram Memory Size
1KB
Cpu Speed
8MHz
No. Of Timers
2
Embedded Interface Type
SCI, SPI
No. Of Pwm Channels
1
Rohs Compliant
Yes
Processor Series
ST72F3x
Core
ST7
Data Bus Width
8 bit
Data Ram Size
1024 B
Interface Type
SCI, SPI
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
32
Number Of Timers
4 bit
Operating Supply Voltage
3.8 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Development Tools By Supplier
ST7F521-IND/USB, ST7232X-EVAL, ST7MDT20-DVP3, ST7MDT20J-EMU3, STX-RLINK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
Cpu Family
ST7
Device Core Size
8b
Frequency (max)
8MHz
Total Internal Ram Size
1KB
# I/os (max)
32
Number Of Timers - General Purpose
2
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
3.8V
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
44
Package Type
TQFP
For Use With
497-8222 - UPS (LINE INTERACTIVE - 450W)497-8436 - BOARD EVAL UPS 450W VOUT=220V497-6421 - BOARD EVAL DGTL BATT CHGR DESIGN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
In Transition
Other names
497-2108

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST72F324J6T6
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
ST72F324J6T6
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
ST72F324J6T6
Quantity:
960
Company:
Part Number:
ST72F324J6T6
Quantity:
960
Part Number:
ST72F324J6T6/TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
ST72324Jx ST72324Kx
SYSTEM INTEGRITY MANAGEMENT (Cont’d)
6.4.2 Auxiliary Voltage Detector (AVD)
The Voltage Detector function (AVD) is based on
an analog comparison between a V
V
ply. The V
lower than the V
age in order to avoid parasitic detection (hystere-
sis).
The output of the AVD comparator is directly read-
able by the application software through a real
time status bit (AVDF) in the SICSR register. This
bit is read only.
Caution: The AVD function is active only if the
LVD is enabled through the option byte (see
tion 14.1 on page
6.4.2.1 Monitoring the V
The AVD voltage threshold value is relative to the
selected LVD threshold configured by option byte
(see
If the AVD interrupt is enabled, an interrupt is gen-
erated when the voltage crosses the V
V
Figure 16. Using the AVD to Monitor V
28/164
1
IT+(AVD)
IT-(AVD)
AVDF bit
AVD INTERRUPT
REQUEST
IF AVDIE bit = 1
LVD RESET
V
V
V
V
IT+(AVD)
IT+(LVD)
IT-(LVD)
IT-(AVD)
threshold (AVDF bit toggles).
reference value and the V
IT-
reference value for falling voltage is
V
DD
IT+
150).
reference value for rising volt-
0
DD
Main Supply
1
DD
INTERRUPT PROCESS
IT-(AVD)
IT+(AVD)
main sup-
V
Early Warning Interrupt
(Power has dropped, MCU not
not yet in reset)
DD
hyst
Sec-
RESET VALUE
and
or
In the case of a drop in voltage, the AVD interrupt
acts as an early warning, allowing software to shut
down safely before the LVD resets the microcon-
troller. See
The interrupt on the rising edge is used to inform
the application that the V
If the voltage rise time t
CPU cycles (depending on the reset delay select-
ed by option byte), no AVD interrupt will be gener-
ated when V
If t
– If the AVD interrupt is enabled before the
– If the AVD interrupt is enabled after the V
V
rupts will be received: the first when the AVDIE
bit is set, and the second when the threshold is
reached.
threshold is reached then only one AVD interrupt
will occur.
rv
IT+(AVD)
is greater than 256 or 4096 cycles then:
threshold is reached, then 2 AVD inter-
Figure
IT+(AVD)
t
1
16.
rv
VOLTAGE RISE TIME
is reached.
rv
DD
is less than 256 or 4096
warning state is over.
INTERRUPT PROCESS
0
IT+(AVD)

Related parts for ST72F324J6T6