ATTINY13A-SS7 Atmel, ATTINY13A-SS7 Datasheet - Page 86

IC MCU AVR 1K FLASH 8SOIC

ATTINY13A-SS7

Manufacturer Part Number
ATTINY13A-SS7
Description
IC MCU AVR 1K FLASH 8SOIC
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY13A-SS7

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
6
Program Memory Size
1KB (512 x 16)
Program Memory Type
FLASH
Eeprom Size
64 x 8
Ram Size
64 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
8-SOIC (3.9mm Width)
Processor Series
ATtiny
Core
AVR
Data Bus Width
8 bit
Data Ram Size
64 B
Interface Type
SPI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
6
Number Of Timers
1
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 105 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Connectivity
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY13A-SS7R
Manufacturer:
Atmel
Quantity:
8 052
86
ATtiny13A
When Auto Triggering is used, the prescaler is reset when the trigger event occurs, as shown in
Figure 14-6
this mode, the sample-and-hold takes place two ADC clock cycles after the rising edge on the
trigger source signal. Three additional CPU clock cycles are used for synchronization logic.
Figure 14-6. ADC Timing Diagram, Auto Triggered Conversion
In Free Running mode, a new conversion will be started immediately after the conversion com-
pletes, while ADSC remains high.
Figure 14-7. ADC Timing Diagram, Free Running Conversion
Cycle Number
ADC Clock
Trigger
Source
ADATE
ADIF
ADCH
ADCL
Prescaler
Reset
Cycle Number
ADC Clock
ADSC
ADIF
ADCH
ADCL
below. This assures a fixed delay from the trigger event to the start of conversion. In
MUX and REFS
Update
1
Conversion
Complete
2
One Conversion
11
3
Sample &
Hold
4
12
5
13
6
7
One Conversion
Next Conversion
1
Sign and MSB of Result
LSB of Result
8
9
2
MUX and REFS
Update
10
Conversion
Complete
3
11
Sample & Hold
12
4
13
Sign and MSB of Result
LSB of Result
8126E–AVR–07/10
Next Conversion
1
Prescaler
Reset
2