ATTINY13A-SS7 Atmel, ATTINY13A-SS7 Datasheet - Page 109

IC MCU AVR 1K FLASH 8SOIC

ATTINY13A-SS7

Manufacturer Part Number
ATTINY13A-SS7
Description
IC MCU AVR 1K FLASH 8SOIC
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY13A-SS7

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
6
Program Memory Size
1KB (512 x 16)
Program Memory Type
FLASH
Eeprom Size
64 x 8
Ram Size
64 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
8-SOIC (3.9mm Width)
Processor Series
ATtiny
Core
AVR
Data Bus Width
8 bit
Data Ram Size
64 B
Interface Type
SPI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
6
Number Of Timers
1
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 105 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Connectivity
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY13A-SS7R
Manufacturer:
Atmel
Quantity:
8 052
Table 17-9.
Note:
17.7
8126E–AVR–07/10
Instruction
Read Fuse Byte
Write Fuse Byte
Read Signature Byte
Read Calibration Byte
Poll RDY/BSY
a = address high bits, b = address low bits, H = 0 - Low byte, 1 - High Byte, o = data out, i = data in, x = don’t care
High-Voltage Serial Programming
Serial Programming Instruction Set (Continued)
This section describes how to program and verify Flash Program memory, EEPROM Data mem-
ory, lock bits and fuse bits in the ATtiny13A.
Figure 17-2. High-voltage Serial Programming
0101 H000
1010 1100
0011 0000
0011 1000
1111 0000
Byte 1
SCI
0000 H000
1010 H000
0000 0000
000x xxxx
000x xxxx
+11.5 - 12.5V
Byte 2
Instruction Format
0000 000b
xxxx xxbb
xxxx xxxx
xxxx xxxx
xxxx xxxx
Byte 3
PB5
PB3
GND
(RESET)
oooo oooo
oooo oooo
oooo oooo
xxxx xxxo
Byte4
iiii iiii
VCC
PB2
PB1
PB0
Operation
Read fuse low/high byte. Bit “0” =
programmed, “1” = unprogrammed.
See
details.
Set fuse low/high byte. Set bit to “0” to
program, “1” to unprogram. See
Bytes” on page 104
Read Signature Byte o at address b.
Read Calibration Byte. See
“Calibration Bytes” on page 105
If o = “1”, a programming operation is
still busy. Wait until this bit returns to
“0” before applying another command.
+1.8 - 5.5V
“Fuse Bytes” on page 104
SDO
SII
SDI
for details.
for
“Fuse
109

Related parts for ATTINY13A-SS7