PDH10-37 Panduit Corp, PDH10-37 Datasheet - Page 31

no-image

PDH10-37

Manufacturer Part Number
PDH10-37
Description
HOSE AIR SUPPLY
Manufacturer
Panduit Corp
Type
Accessory, Hoser
Datasheet

Specifications of PDH10-37

Features
-
For Use With/related Products
-
Tie in hose - press air
burst
Blocked hose - failed
back pressure test
Blocked or dirty exit
sensor
Blocked or dirty tool
sensor
Tie stuck in exit
sensor
Tie stuck in tool
sensor
Detent sensor
blocked or dirty
Internal regulator
incorrectly set, low
Internal regulator
incorrectly set, high
*If the cable tie does not come out freely, turn the dispenser "off" and then "on" again, to reset the rotary receiver's position.
MESSAGE
PAT1M/PAT1.5M: PA22222A01_03
Cable tie is caught or remains in
feeder hose upon actuation due to
a severe bend or twist in the feeder
hose, low air pressure, or an
interrupted cycle.
Tool was actuated while a cable tie
(or ties) was still in the feeder hose.
Exit (optical) sensor in the
dispenser is obstructed due to a
cable tie or excess debris (dirt,
grime).
Tool (optical) sensor is obstructed
due to a cable tie or excess debris
(dirt, grime).
The dispenser exit sensor in is
blocked so that a cable tie cannot
exit the dispenser. It may be
blocked by another cable tie that
was not removed from an earlier
cycle.
Cable tie has stopped in the tool
sensor area of tool.
Tip collector full. Detent sensor
blocked by detent cam, foreign
object, or detent sensor lens is
dirty.
Internal regulator was adjusted
incor-rectly, or the piston is not fully
shifting.
Internal regulator was adjusted
incorrectly.
POSSIBLE CAUSE
PAT1M / PAT1.5M OPERATION MANUAL
Page: 29 of 36
1. Press "Buzzer" button to turn buzzer "off".
2. Straighten feeder hose to eliminate any bends or twists, and
3. Press "Air burst" button to dislodge and advance cable tie to
4. Press "Buzzer" button to turn buzzer "off".
5. Remove cable tie from jaw area and press the "Continue"
6. Press "Load" button to load one (1) cable tie and resume
7. If the cable tie does not advance to the tool jaw area after
Follow corrective action for "Tie in hose - press air burst" error
above.
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect feeder hose from dispenser. Look for cable tie
3. If the same error is repeated, clean the dispenser exit
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect feeder hose from tool. Look for cable tie in tool
3. If the same error is repeated, the tool sensor lens may
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect air hose and feeder hose from dispenser. Look
3. If the same error is repeated, clean the dispenser exit
1. Press "Buzzer" button to turn buzzer "off".
2. Follow corrective action for "Blocked or dirty tool sensor"
1. Press "Buzzer" button to turn buzzer "off".
2. Remove cable tie from jaw area of tool.
3. Press the "Continue" button and resume operation.
4. If message reappears, notify maintenance department.
1. Press "Buzzer" button to turn buzzer 'off" and resume
2. If message remains, system will not operate. Write down
point tool away from yourself and others.
jaw area of tool. Press several times, if necessary. When
cable tie is advanced to jaw area, "Tie in tool" message will
appear and buzzer will sound.
button.
operation.
depressing the "Air Burst" button several times, replace
the feeder hose with another and notify your maintenance
department.
in dispenser connector block and remove cable tie, if
present.* Reconnect feeder hose, and resume operation. If
cable tie is not found, reconnect feeder hose. Follow the
same Corrective Action for "Tie in hose - press air burst"
error to remove the cable tie from the system.
sensor lens (Refer to the Cleaning the Dispenser Exit
Sensor Lens section on Page 26).
or tool end of hose and remove cable tie, if present.
Reconnect feeder hose, and resume operation. If cable tie
is not found, reconnect feeder hose. Follow the same
Corrective Action for "Tie in hose - press air burst" error to
remove the cable tie from the system.
require cleaning. Contact your maintenance department to
have the tool sensor lens cleaned.
for cable tie in dispenser connector block and remove cable
tie, if present.* Reconnect air hose and feeder hose, and
resume operation. If cable tie is not found, reconnect air
hose and feeder hose. Follow the same Corrective Action
for "Tie in hose -press air burst" error to remove the cable
tie from the system.
sensor lens (Refer to the Cleaning the Dispenser Exit
Sensor Lens section on Page 26).
error above.
operation.
message and notify maintenance department.
CORRECTIVE ACTION
Dec., 2007