Specifications of PDH10-37

Features
-
For Use With/related Products
-
ERROR 3 - Check for low air pressure
POSSIBLE CAUSE: This message will be displayed if the incoming air pressure is too low, or not connected.
CORRECTIVE ACTION: Press the "Buzzer" button to turn the buzzer signal "off". Increase the air pressure to 65
PSIG (4,5 bar).
PREVENTION: To prevent this problem from recurring, verify that the air line is connected, and the air pressure is
between 65 and 85 PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 4 - Check for high air pressure
POSSIBLE CAUSE: This message will be displayed if the incoming air pressure is too high.
CORRECTIVE ACTION: Press the "Buzzer" button to turn the buzzer signal "off". Decrease the air pressure to
below 85 PSIG (5,8 bar).
PREVENTION: To prevent this problem from recurring, verify that the air pressure is between 65 and 85 PSIG (4,5
and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 5 - Dispenser jam - check tie loading
POSSIBLE CAUSE: This occurs if the dispenser rotary receiver is prevented from advancing (rotating) to the next
position. This may be caused by a jam due to bowed or misaligned cable ties feeding into the rotary receiver, or a jam
due to a backed-up cable tie carrier strip in the carrier strip exit chute.
CORRECTIVE ACTION: Press the "Buzzer" button to turn the buzzer signal "off". At this point, check the rotary
receiver and connection block for misaligned or jammed cable ties, and check that the carrier strip scrap chute is
clear. Press the "Unload" button to back the cable ties out until the jam and all remaining loose cable ties are
cleared from the rotary receiver. Cut the excess carrier strip and any distorted or damaged cable ties from the cable
tie strip. Close the dispenser cover and perform the normal loading procedure.
PREVENTION: To prevent this problem from recurring, load the dispenser with care to prevent misaligned cable ties
in the rotary receiver, and empty the carrier strip scrap bin every 1/2 reel of cable ties.
ERROR 6 - Tie in tool
POSSIBLE CAUSE: This occurs if the cable tie reaches the tool but is prevented from completing the cycle. This
may be due to a large air pressure drop, too large of a bundle, improper feeder hose connections, an obstruction
blocking the cable tie path, a severe bend or twist in the feeder hose, or the tool jaws are opened during the cycle.
CORRECTIVE ACTION: Remove the cable tie and any obstruction from the jaw area. Resume operation.
PAT1M/PAT1.5M: PA22222A01_03
Check for low air pressure
Check for high air pressure
Dispenser jam - check tie loading
Tie in tool
Load
Load
Load
Help
PAT1M / PAT1.5M OPERATION MANUAL
Unload
Unload
Unload
Unload
MENU
MENU
Buzzer
Buzzer
Page: 17 of 36
Buzzer
Buzzer
Continue
Continue
Dec., 2007