I310S Fluke Electronics, I310S Datasheet - Page 3

no-image

I310S

Manufacturer Part Number
I310S
Description
CURRENT PROBE AC/DC
Manufacturer
Fluke Electronics
Type
AC/DC Clamp, Hall Effectr
Datasheet

Specifications of I310S

Style
Pincer
Ac Current Range
30 ~ 300A rms
Bandwidth
20kHz
Cable Length
78.740" (2000.00mm)
Dc Current Range
45A ~ 450A
Max Conductor Size
0.748" (19.00mm)
Termination
BNC
Ratings
CAT III 300V
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2840309
Specifications
Electrical Characteristics
All accuracies stated at 23°C ± 1°C (73.4 °F ± 33.8 °F)
Current Range
Inrush Current
Output Sensitivity
Accuracy
Bandwidth to Meet
Accuracy
Specification
Phase Shift below 1
kHz
Resolution
Load impedance
Conductor Position
Sensitivity
Frequency Range
(small signal)
Temperature
Coefficient
Power Supply
Working Voltage
Battery Life
CAT III equipment is designed to protect against
the transients in the equipment in fixed
equipment installations, such as distribution
panels, feeders and short branch circuits, and
the lighting systems in large buildings.
Do not use Clamp in wet environments or in
locations that hazardous gases exist.
30 A and 300 A ac rms or
± 45 A and 450 A dc
600 A ac rms Max
10 mV/A (30 A)
1 mV/A (300 A)
(30 A range) ± 1 % of reading ± 50 mA
(300 A range) ± 1 % of reading ± 300 mA
@25 °C, Bandwidth dc to 1 kHz
1 kHz
< 2 degrees
± 50 mA (30 A)
± 100 mA (300 A)
> 10 k
± 1.5 % relative to center reading
DC to 20 kHz (-3 dB)
± 0.01 % of reading / °C
9 V Alkaline, NEDA 1604/PP3 IEC 6LR61
300 V ac rms or dc
30 hours, low battery indicator
and
100 pF