LD2T06P0 Red Lion Controls, LD2T06P0 Datasheet - Page 2

TIMER 6 DIGIT 2.25" 120VAC RED

LD2T06P0

Manufacturer Part Number
LD2T06P0
Description
TIMER 6 DIGIT 2.25" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Timerr
Datasheet

Specifications of LD2T06P0

No. Of Digits / Alpha
6
Digit Height
57mm
Power Consumption
26VA
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
2.25"
Ip/nema Rating
IP65 / NEMA 4X
Accuracy
±0.01% %
Connection Type
Wire Leads
Dimensions
16"L×2.25"W×4"H
Display Digit Height
2.25 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Material, Casing
Aluminum
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Display Font Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC119
5. TIMER SIGNAL INPUTS (INP A and INP B)
6. RESET/USER INPUT Programmable Function Input:
7. COMMUNICATIONS:
8. MEMORY: Nonvolatile E
9. OUTPUT:
10. CONNECTIONS:
INSTALLATION
INSTALLATION ENVIRONMENT
temperature. Placing the unit near devices that generate excessive heat should be
avoided. The unit should only be cleaned with a soft cloth and neutral soap
product. Do NOT use solvents.
the front overlay. Do not use tools of any kind (screwdrivers, pens, pencils, etc.)
to operate the keypad of the unit.
1.0 I
Maximum Count Rate:
DIP switch selectable pull-up (7.8 K) or pull-down (3.9 K) resistors
Input A Trigger levels: V
Input B: Trigger levels: V
Inputs A and B:
DIP switch selectable pull-up (7.8 K) or pull-down (3.9 K) resistor
Trigger levels: V
Response Time: 10 msec typ.; 50 msec debounce (activation and release)
RS485 SERIAL COMMUNICATIONS
RS232 SERIAL COMMUNICATIONS
timer/count values when power is removed.
Relay: Form C contacts rated at 5 amps @ 120/240 VAC or 28 VDC (resistive
Internal removable terminal blocks are used for power and signal wiring.
Remove end plates with ¼" nut driver. For LD4 versions, all wiring is on right
side of unit. For LD2 versions, power and signal wiring connections are on
the right side and the relay and serial output options are on left side.
Wire Strip Length: 0.4" (10 mm)
Wire Gage: 24-12 AWG copper wire, 90°C rated insulation only
Torque: 5.3 inch-lbs (0.6 N-m) max
Cable Diameter: Outside diameter must be 0.181" (4.6 mm) to 0.312" (7.9
The meter meets NEMA 4X/IP65 requirements when properly installed.
The unit should be installed in a location that does not exceed the operating
Continuous exposure to direct sunlight may accelerate the aging process of
All Count Sources except Input B: 10 Hz
Input B Count Source:
determine active high or active low input logic.
Timer Input Pulse Width: 1 msec min.
Timer Start/Stop Response Time: 1 msec max.
Filter: Software filtering provided for relay or switch contact debounce.
Type: RS485 multi-point balanced interface (isolated)
Baud Rate: 300 to 38400
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
Type: RS232 half duplex (isolated)
Baud Rate: 300 to 38400
Data Format: 7/8 bits; odd, even, or no parity
load), 1/8 H.P. @ 120 VAC (inductive load)
mm) to maintain NEMA 4 rating of cord grips.
that determines active high or active low input logic.
With Timer Input Filter ON:
With Timer Input Filter OFF: 500 Hz
Filter enabled or disabled through programming. If enabled, results in
50 msec start/stop response time for successive pulses applied to the
same input terminal.
NSTALLING THE
IL
= 1.0 V max; V
IL
IL
= 1.25 V max; V
2
= 1.0 V max; V
PROM retains all programming parameters and
IH
10 Hz
ORDERING INFORMATION
= 2.4 V min; V
MODEL NO.
LD Plug
LD
IH
IH
= 2.75 V min; V
= 2.4 V min; V
DESCRIPTION
2.25" High 6-Digit Red LED Timer/Cycle Counter w/ Relay Output &
RS232/RS485 Serial Communications
4" High 6-Digit Red LED Timer/Cycle Counter w/ Relay Output &
RS232/RS485 Serial Communications
Panel Meter Plug for LD models
MAX
= 28 VDC
MAX
MAX
M
= 28 VDC
= 28 VDC
ETER
2
11. ENVIRONMENTAL CONDITIONS:
12. CERTIFICATIONS AND COMPLIANCES:
13. CONSTRUCTION: Aluminum enclosure, and steel side panels with textured
14. WEIGHT:
MOUNTING INSTRUCTIONS
wall mounted or suspended
from a ceiling truss or other
suitable structure capable
of supporting the LDT.
Caution should be exercised
when hanging the display to
provide for the safety of
personnel. If hanging the LDT,
run the suspension cables (or
chains) through the mounting
bracket holes. For wall mounting
use #10-32 size bolts.
Operating temperature: 0 to 65 °C
Storage temperature: -40 to 70 °C
Operating and storage humidity: 0 to 85% max. RH (non-condensing)
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g’s (10g relay), 11 msec in
Altitude: Up to 2,000 meters
SAFETY
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for
IP65 Enclosure rating, IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Notes:
black polyurethane paint for scratch and corrosion resistance protection. Meets
NEMA 4X/IP65 specifications. Installation Category II, Pollution Degree 2.
LD2T06P0 - 4.5 lbs (2.04 kg)
LD4T06P0 - 10.5 lbs (4.76 kg)
This display is designed to be
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Voltage dip/interruptions
Emissions:
Emissions
direction for 1.5 hours, 2 g’s (1g relay).
3 directions.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating, UL50
measurement, control, and laboratory use, Part 1.
Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN61000-4-11
EN 55011
PART NUMBER
LDPLUG00
LD2T06P0
LD4T06P0
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion A
10 V/m
Criterion A
2 kV power
1 kV signal
Criterion A
1 kV L-L,
Criterion A
3 V/rms
Criterion A
0.5 cycle
Class B
2 kV L&N-E power
MOUNTING HOLE (.281")
TERMINAL #3 (TBA)
MUST BE
CONNECTED TO

Related parts for LD2T06P0