G6Z-1FE-A DC12 Omron, G6Z-1FE-A DC12 Datasheet - Page 5

RELAY HI FREQ 50 OHM SMD

G6Z-1FE-A DC12

Manufacturer Part Number
G6Z-1FE-A DC12
Description
RELAY HI FREQ 50 OHM SMD
Manufacturer
Omron
Series
G6Zr
Datasheets

Specifications of G6Z-1FE-A DC12

Relay Type
RF
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
0.01A @ 30VAC/DC
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
12VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Coil Frequency Max
2.6GHz
Coil Voltage Vdc Nom
12V
Contact Current Max
500mA
Contact Voltage Ac Nom
30V
Contact Voltage Dc Nom
30V
Coil Resistance
720ohm
Contact Configuration
SPDT
Contact Form
SPDT (1 Form C)
Contact Rating (current)
0.01A
Switching Voltage
30VAC, 30VDC - Max
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Features
Sealed - Fully
Contact Material
Copper (Cu), Gold (Au)
Operate Time
10ms
Release Time
10ms
Coil Power
200 mW
Operating Temperature
-40°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6Z-1FE-ADC12
G6Z1FEADC12
G6Z
I
Note:
Note:
Engineering Data
122
Contact resistance (See note 1.)
Operating (set) time (See note 2.)
Release (reset) time (See note 2.)
Minimum set/reset pulse time
Insulation resistance (See note 3.)
Dielectric
strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Ambient Temperature vs.
Maximum Voltage
250
200
150
100
Characteristics
50
0
−40
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
−20
the dielectric strength.
0
Coil and contacts
Coil and ground, contacts
and ground
Contacts of same polarity
Item
20
Ambient temperature (°C)
40
60
G6Z
G6ZU
G6ZK
80
100
100 m Ω max.
10 ms max. (approx. 3.5 ms) 10 ms max. (approx. 2.5 ms)
10 ms max. (approx. 2.5 ms)
---
100 M Ω min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
Destruction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s
Malfunction:500 m/s
Mechanical:1,000,000 operations min. (at 36,000 operations/hour)
Electrical: 300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations
Operating: − 40 ° C to 70 ° C (with no icing or condensation)
Operating: 5% to 85%
Approx. 2.8 g
Ambient Temperature vs. Must
Operate or Must Release Voltage
Single-side stable models
100
G6Z-1P(E), G6Z-1F(E)
90
80
70
60
50
40
30
20
10
0
−60
Sample: G6Z-1P 5 VDC
Number of relays: 5
−40
min. (900 MHz, 10 W) at a switching frequency of 1,800 operations/hour
−20
0
2
2
20
Ambient temperature (°C)
Max. estimated value
40
12 ms
G6ZU-1P(E), G6ZU-1F(E)
Single-winding latching
60
Must operate voltage
Must release voltage
80 100
max.
max.
avg.
min.
avg.
min.
models
Shock direction
Y'
Conditions: Shock is applied in ±X, ±Y, and ±Z
Y
Shock Malfunction
1,000
1,000
X
Z'
X
X'
Z
Z'
directions three times each with and
without energizing the Relays to check
for contact malfunctions.
Double-winding latching
G6ZK-1P(E), G6ZK-1F(E)
1,000
200
400
600
800
Y
Y'
1,000
800
600
400
200
Not
energized
Unit:
Sample: G6Z-1P-A 50 Ω
Number of relays: 5
models
Energized
m/s
5 VDC
1,000
1,000
2
Z
X'
G6Z