TOOLSTICK542PP Silicon Laboratories Inc, TOOLSTICK542PP Datasheet - Page 221

PLATFORM PROG TOOLSTICK F542

TOOLSTICK542PP

Manufacturer Part Number
TOOLSTICK542PP
Description
PLATFORM PROG TOOLSTICK F542
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
Microcontroller Programmerr
Datasheets

Specifications of TOOLSTICK542PP

Contents
2 Boards and USB Connecting Cable
Processor To Be Evaluated
C8051F542
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F542
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1718
SFR Definition 22.1. SPI0CFG: SPI0 Configuration
SFR Address = 0xA1; SFR Page = 0x00
Note: In slave mode, data on MOSI is sampled in the center of each data bit. In master mode, data on MISO is
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
sampled one SYSCLK before the end of each data bit, to provide maximum settling time for the slave device.
See Table 22.1 for timing parameters.
SPIBSY
SLVSEL
MSTEN
RXBMT
CKPHA
CKPOL
SPIBSY
NSSIN
Name
SRMT
R
7
0
MSTEN
SPI Busy.
This bit is set to logic 1 when a SPI transfer is in progress (master or slave mode).
Master Mode Enable.
0: Disable master mode. Operate in slave mode.
1: Enable master mode. Operate as a master.
SPI0 Clock Phase.
0: Data centered on first edge of SCK period.
1: Data centered on second edge of SCK period.
SPI0 Clock Polarity.
0: SCK line low in idle state.
1: SCK line high in idle state.
Slave Selected Flag.
This bit is set to logic 1 whenever the NSS pin is low indicating SPI0 is the selected
slave. It is cleared to logic 0 when NSS is high (slave not selected). This bit does
not indicate the instantaneous value at the NSS pin, but rather a de-glitched ver-
sion of the pin input.
NSS Instantaneous Pin Input.
This bit mimics the instantaneous value that is present on the NSS port pin at the
time that the register is read. This input is not de-glitched.
Shift Register Empty (valid in slave mode only).
This bit will be set to logic 1 when all data has been transferred in/out of the shift
register, and there is no new information available to read from the transmit buffer
or write to the receive buffer. It returns to logic 0 when a data byte is transferred to
the shift register from the transmit buffer or by a transition on SCK. SRMT = 1 when
in Master Mode.
Receive Buffer Empty (valid in slave mode only).
This bit will be set to logic 1 when the receive buffer has been read and contains no
new information. If there is new information available in the receive buffer that has
not been read, this bit will return to logic 0. RXBMT = 1 when in Master Mode.
R/W
6
0
CKPHA
R/W
5
0
CKPOL
R/W
Rev. 1.1
4
0
SLVSEL
Function
R
3
0
*
NSSIN
*
R
2
1
C8051F54x
SRMT
R
1
1
RXBMT
R
0
1
221