EVAL-ADT7462EBZ ON Semiconductor, EVAL-ADT7462EBZ Datasheet - Page 78

no-image

EVAL-ADT7462EBZ

Manufacturer Part Number
EVAL-ADT7462EBZ
Description
BOARD EVALUATION FOR ADT7462
Manufacturer
ON Semiconductor
Type
Temperature Sensorr
Datasheet

Specifications of EVAL-ADT7462EBZ

Contents
Evaluation Board
For Use With/related Products
ADT7462
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1. POR = 0x00, Lock = N, SW Reset = Y.
1. POR = 0x00, Lock = N, SW Reset = Y.
1. POR = 0x00, Lock = N, SW Reset = Y.
Table 94. Register 0xB9 — Host Thermal Status Register 2
Register 0xC1 — BMC Thermal Status Register 2
Table 95. Register 0xBA — Host Thermal Status Register 3
Table 96. Register 0xBB — Host Voltage Status Register 1
Register 0xC3 — BMC Voltage Register 1
Bit
Bit
Bit
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
THERM1 Assert
THERM2 Assert
THERM1 State
THERM2 State
Local THERM1
Local THERM2
Pin 15 Voltage
Pin 19 Voltage
Pin 23 Voltage
VRD1_Assert
VRD2_Assert
THERM1 %
THERM2 %
Remote 1
Remote 2
Remote 3
Remote 1
Remote 2
Remote 3
THERM1
THERM1
THERM1
THERM2
THERM2
THERM2
+12V1
+12V2
+12V3
Name
Name
Name
+3.3V
+5V
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
A 1 indicates that THERM1 has been asserted for longer than the programmed THERM1 timer
limit.
A 1 indicates that THERM1 is asserted.
A 1 indicates that a transition from high to low has taken place on the THERM1 pin.
A 1 indicates that THERM2 has been asserted for longer than the programmed THERM2 timer
limit.
A 1 indicates that THERM2 is asserted.
A 1 indicates that a transition from high to low has taken place on the THERM2 pin.
A 1 indicates that VRD1 is asserted.
A 1 indicates that VRD2 is asserted.
A 1 indicates that the local THERM1 limit has been exceeded.
A 1 indicates that the Remote 1 THERM1 limit has been exceeded.
A 1 indicates that the Remote 2 THERM1 limit has been exceeded.
A 1 indicates that the Remote 3 THERM1 limit has been exceeded.
A 1 indicates that the Local THERM2 limit has been exceeded.
A 1 indicates that the Remote 1 THERM2 limit has been exceeded.
A 1 indicates that the Remote 2 THERM2 limit has been exceeded.
A 1 indicates that the Remote 3 THERM2 limit has been exceeded.
A 1 indicates that a +12V1 voltage limit has been tripped.
A 1 indicates that a +12V2 voltage limit has been tripped.
A 1 indicates that a +12V3 voltage limit has been tripped.
A 1 indicates that a +3.3V voltage limit has been tripped.
A 1 indicates that a Pin 15 voltage limit has been tripped.
A 1 indicates that a Pin 19 voltage limit has been tripped.
A 1 indicates that a +5V voltage limit has been tripped.
A 1 indicates that a Pin 23 voltage limit has been tripped.
(Note 1)
http://onsemi.com
(Note 1)
78
(Note 1)
(Note 1)
(Note 1)
;
;
Description
Description
Description

Related parts for EVAL-ADT7462EBZ