EVAL-ADT7463EB Analog Devices Inc, EVAL-ADT7463EB Datasheet - Page 36

no-image

EVAL-ADT7463EB

Manufacturer Part Number
EVAL-ADT7463EB
Description
BOARD EVAL FOR ADT7463
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-ADT7463EB

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
ADT7463
Bit
<0>
<1>
<2>
<3>
<4>
<5>
<6>
<7>
*This register becomes read-only when the Configuration Register 1 Lock bit is set to 1. Any subsequent attempts to write to this register will fail.
Name
CYR2
V
PHTR1
PHTL
PHTR2
R1T
LT
R2T
CCP
LO
Table X. Register 0x36 – Dynamic T
R/W
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Description
MSB of 3-Bit Remote 2 Cycle Value. The other two bits of the code reside in Dynamic T
Control Register 2 (Reg. 0x37). These three bits define the delay time between making sub-
sequent T
The system will have associated thermal time constants that need to be found to optimize
the response of fans and the control loop.
V
(V
• Status Bit 1 in Status Register 1 gets set.
• SMBALERT gets generated if enabled.
• PROCHOT monitoring is disabled.
• Dynamic T
• The device is prevented from entering shutdown.
• Everything re-enabled once V
PHTR1 = 1 copies the Remote 1 current temperature to the Remote 1 Operating Point
Register if THERM gets asserted. The operating point will contain the temperature at
which THERM is asserted. This allows the system to run as quietly as possible without
system performance being affected. PHTR1 = 0 ignores any THERM assertions on the
THERM pin. The Remote 1 Operating Point Register will reflect its programmed value.
PHTL = 1 copies the local channel’s current temperature to the Local Operating Point
Register if THERM gets asserted. The operating point will contain the temperature at
which THERM is asserted. This allows the system to run as quietly as possible without
system performance being affected. PHTL = 0 ignores any THERM assertions on the
THERM pin. The Local Temp Operating Point Register will reflect its programmed value.
PHTR2 = 1 copies the Remote 2 current temperature to the Remote 2 Operating Point
Register if THERM gets asserted. The operating point will contain the temperature at
which THERM is asserted. This allows the system to run as quietly as possible without
system performance being affected. PHTR2 = 0 ignores any THERM assertions on the
THERM pin. The Remote 2 Operating Point Register will reflect its programmed value.
R1T = 1 enables dynamic T
chosen T
ating point, and high and low limits for this zone. R1T = 0 disables dynamic T
trol. The T
in the Automatic Fan Control section.
LT = 1 enables dynamic T
T
point, and high and low limits for this zone. LT = 0 disables dynamic T
T
Automatic Fan Control section.
R2T = 1 enables dynamic T
chosen T
operating point, and high and low limits for this zone. R2T = 0 disables dynamic T
control. The T
described in the Automatic Fan Control section.
CCP
MIN
MIN
CCP
LO = 1. When the power is supplied from 3.3VSTANDBY and the core voltage
value chosen will not be adjusted and the channel will behave as described in the
) drops below its V
value will be dynamically adjusted based on the current temperature, operating
MIN
MIN
MIN
MIN
value will be dynamically adjusted based on the current temperature, oper-
value will be dynamically adjusted based on the current temperature,
MIN
adjustments in the control loop, in terms of number of monitoring cycles.
MIN
value chosen will not be adjusted and the channel will behave as described
MIN
control is disabled.
value chosen will not be adjusted and the channel will behave as
Control Register 1 (Power-On Default = 0x00)
–36–
CCP
MIN
MIN
MIN
low limit value (Reg. 0x46), the following occurs:
control on the Local Temperature channel. The chosen
CCP
control on the Remote 1 Temperature channel. The
control on the Remote 2 Temperature channel. The
increases above V
CCP
low limit.
MIN
control. The
MIN
REV. B
con-
MIN
MIN